background image

3

JCB-IT30, JCB-IT50
Instruction Manual

SPECIFICATION

JCB-IT30

JCB-IT50

Power Output

30W

50W

Lumen Output

2200lm

4000lm

Beam Angle

60º

IP Rating

IP65

Charge Time 

4-5 hours / battery

5-6 hours / battery

Run Time

2-2.5 Hours High

7-8  Hours Low

2-2.5 Hours High

7-8 Hours Low

Input Voltage

100-240V, 50Hz

Material

Aluminium

LED

30W COB 

50W COB

CRI

70Ra

Power Factor

0.9

Colour Temp

6500K

IK Rating

IK09

Life Expectancy

20,000 Hours

Working Temp.

-10ºC - 40ºC

Battery

1 x 11.1V 4000mAh

1 x 14.8V 5200mAh

PCB Protection

Charging / Discharging Protection

Dimensions

W250 x H158 x D95mm 

W302 x H197 x D100mm

Charger

12.6V, 1A, AC/DC

16.8V, 1A, AC/DC

Weight 

1.5Kg

2.5Kg

Features 

• 

Carry handle

• 

Mounting bracket

• 

Sturdy base

Summary of Contents for JCB-IT30

Page 1: ...EN JCB IT30 JCB IT50 LED RECHARGEABLE INDUSTRIAL TASK LIGHTS LED WORKLIGHTS INSTRUCTION MANUAL...

Page 2: ...ilable in 30W 50W versions offering up to 4000lm light output The range is available with either an 11 1V or 14 8V battery delivering runtime of up to eight hours from a 4 6 hour charge time The produ...

Page 3: ...High 7 8 Hours Low Input Voltage 100 240V 50Hz Material Aluminium LED 30W COB 50W COB CRI 70Ra Power Factor 0 9 Colour Temp 6500K IK Rating IK09 Life Expectancy 20 000 Hours Working Temp 10 C 40 C Bat...

Page 4: ...0 Planar Intensity Distribution Curve 0 2093 0 5 3 4 0 0 0 1 0 0 0 0 0 0 Position 180 0 7 0 Up Flux Rate 0 0 C0 Plane beam angle 50 66 9 DEG C90 Plane beam angle 50 67 2 DEG C0 Plane beam angle 50 C90...

Page 5: ...Planar Intensity Distribution Curve 0 3457 1 9 1 4 0 0 0 1 0 0 0 0 0 0 Position 180 0 7 0 Up Flux Rate 0 0 C0 Plane beam angle 50 66 9 DEG C90 Plane beam angle 50 70 3 DEG C0 Plane beam angle 50 C90 P...

Page 6: ...r service the battery DO NOT expose to temperatures below 10 C or above 40 C DO NOT crush puncture short external contacts or dispose of in fire or water DO NOT dispose of with regular waste dispose o...

Page 7: ...power supply DO NOT use if worn or damaged Check cables are always protected against short circuit and overload IMPORTANT Check that the voltage marked on the charger plug is the same as the power su...

Page 8: ...socket located on the rear of worklight Connect the 230V charger to a power supply Disconnect the charger from the worklight when it is fully charged and replace the dust cap DO NOT shine the product...

Page 9: ...anual provided The product has not been subject to insufficient servicing and maintenance The product has not been subject to any abnormal environmental conditions or inappropriate operating condition...

Page 10: ...10 JCB IT30 JCB IT50 Instruction Manual NOTES...

Page 11: ...11 JCB IT30 JCB IT50 Instruction Manual NOTES...

Page 12: ...12 JCB IT30 JCB IT50 Instruction Manual NOTES...

Reviews: