background image

4

JCB-IT30, JCB-IT50

Instruction Manual

JCB-IT30

AVERAGE ILLUMINATION

PLANAR INTENSITY DISTRIBUTION CURVE

Bare Lamp Photometric Data

Page 1 Of 

Goniophotometer Test Report

Measured Para  U: 0.0V  I: 0.0mA  P: 0.00W  PF: 0.000 

Lamp Name: 

Shape Size: 

Sur(m^2): 

Lamp Type: 

Lamp Spec: 

Manufactory: 

Weight(kg): 

Lamp ID: 

Protect Angle(Deg): 

a

t

a

D

 

c

i

r

t

e

m

o

t

o

h

P

a

t

a

D

 

e

c

r

u

o

S

 

t

h

g

i

L

Model

Nominal P(w)

Rated Flux(lm)

Illuminant QTY

Peak Value(cd)

Dw Flux Rate(%)

Down(C180-C360)

Efficiency(lm/w)

UP(C0-C180)

UP(C180-C360)

0.0

0.0

Planar Intensity Distribution Curve

0

2093.0

5

.

3

4

0

.

0

0

1

0.0

0.0

0.0

Position

180.0,7.0

Up Flux Rate(%)

0.0

C0 Plane beam angle(50%):66.9(DEG)  C90 Plane beam angle(50%):67.2(DEG)

C0 Plane beam angle(50%)

C90 Plane beam angle(50%)

30°

60°

90°

120°

150°

180°

210°

240°

270°

300°

330°

2,100

1,680

1,260

840

420

0

C Angle Range:0 - 180(Deg)

0

9

 

:

)

g

e

D

(

l

a

v

r

e

t

n

i

 

C

1

 

:

)

g

e

D

(

l

a

v

r

e

t

n

i

 

a

m

a

G

Temperature(Deg): 27

Tester: 

Test System: ZWL Goniophotometer System V3.0

Humidity(%): 50

Date: 2019-7-25

Gama Angle Range:-90 - 90(Deg)

 

:

k

r

a

m

e

R

7

0

.

0

1

 

:

)

m

(

e

c

n

a

t

s

i

D

4

Summary of Contents for JCB-IT30

Page 1: ...EN JCB IT30 JCB IT50 LED RECHARGEABLE INDUSTRIAL TASK LIGHTS LED WORKLIGHTS INSTRUCTION MANUAL...

Page 2: ...ilable in 30W 50W versions offering up to 4000lm light output The range is available with either an 11 1V or 14 8V battery delivering runtime of up to eight hours from a 4 6 hour charge time The produ...

Page 3: ...High 7 8 Hours Low Input Voltage 100 240V 50Hz Material Aluminium LED 30W COB 50W COB CRI 70Ra Power Factor 0 9 Colour Temp 6500K IK Rating IK09 Life Expectancy 20 000 Hours Working Temp 10 C 40 C Bat...

Page 4: ...0 Planar Intensity Distribution Curve 0 2093 0 5 3 4 0 0 0 1 0 0 0 0 0 0 Position 180 0 7 0 Up Flux Rate 0 0 C0 Plane beam angle 50 66 9 DEG C90 Plane beam angle 50 67 2 DEG C0 Plane beam angle 50 C90...

Page 5: ...Planar Intensity Distribution Curve 0 3457 1 9 1 4 0 0 0 1 0 0 0 0 0 0 Position 180 0 7 0 Up Flux Rate 0 0 C0 Plane beam angle 50 66 9 DEG C90 Plane beam angle 50 70 3 DEG C0 Plane beam angle 50 C90 P...

Page 6: ...r service the battery DO NOT expose to temperatures below 10 C or above 40 C DO NOT crush puncture short external contacts or dispose of in fire or water DO NOT dispose of with regular waste dispose o...

Page 7: ...power supply DO NOT use if worn or damaged Check cables are always protected against short circuit and overload IMPORTANT Check that the voltage marked on the charger plug is the same as the power su...

Page 8: ...socket located on the rear of worklight Connect the 230V charger to a power supply Disconnect the charger from the worklight when it is fully charged and replace the dust cap DO NOT shine the product...

Page 9: ...anual provided The product has not been subject to insufficient servicing and maintenance The product has not been subject to any abnormal environmental conditions or inappropriate operating condition...

Page 10: ...10 JCB IT30 JCB IT50 Instruction Manual NOTES...

Page 11: ...11 JCB IT30 JCB IT50 Instruction Manual NOTES...

Page 12: ...12 JCB IT30 JCB IT50 Instruction Manual NOTES...

Reviews: