Troubleshooting/FAQs
Issue / FAQ
Resolution/Answer
I can’t select the reverse steer option
Reverse steer can only be operated in site mode. To select the function,
the machine has to be travelling at less than 1kph (Figure 15)
I can’t enable Highway mode
To enable Highway mode:
• The machine must be stationary
• Slew must be centred & controls in neutral
• The machine must not be in reverse steer mode
Why won’t my stabilisers work?
Ensure that the machine hydraulics (2Go) are on and the machine is in site mode
(Figure 11)
I have moved the switch but the steer
mode hasn’t changed
For steer mode to change, the machines wheels must align in its central position
(Figure 15)
My machine will not start
Ensure the correct start up sequence has been followed as shown previously
(Page 11)
Why is there an audible buzzer in the
cab when I’m lifting a large load?
The boom ram pressure has exceeded 155bar or the dipper is above
horizontal. The buzzer is a warning
I can’t reposition the excavator end
Are you in Highway mode? The excavator end can be overridden by holding
the dozer button or AUX on LH Joystick (a buzzer will sounding indicating the
over ride) (Figure 7)
I can’t activate the Hydraulics
There are many reasons as to why your 2Go may not work when pressing the
button on Keypad 1. Here are some of the following possible reasons:
• If the side pod is lifted and put back down when machine hydraulics are “on”,
machine hydraulics will disable and not function again until side pod down and
machine in neutral.
• The side pod is in the raised position
• The machine is in Highway mode
• There is a fault on the keypad
• Engine isn’t switched on
• If there is an error on the machine and an error code is displayed on the LCD
screen –which would inhibit the hydraulics
• If none of the above, contact dealer