jcb 409ZX Parts And Service Manual Download Page 21

 
 

 

 

20 

JCB   

409ZX Loader    

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BREATHESAFE SYSTEM TROUBLE SHOOTING GUIDE *TOUCH CONTROL 

FAULT 

POSSIBLE CAUSE 

SOLUTION 

*ERR error code

 

  

Poor sensor connection 

Remove & refit pod connection cable 

Corrupted coding 

Access factory setup - default reset - pin 6759 

*Check filter alarm 

Service hour timeout 

Access 

Check Runtime

 menu - reset hours via 7597 code 

Temperature / CO2 error 

Sensor not connected 

Fit sensor or disable via site access CO2 & or temperature menu 

Pressuriser running at full speed/noisy

 

 

 

 

 

 

 

 

 

  

Filter blocked 

Service filter 

Door or window open 

Ensure doors & windows securely shut 

Cabin sealing capacity not adequate 

Perform pressure test procedure & seal leak points as required 

Sense pipe blocked 

Ensure clear & not bent 

Internal sensor damaged 
  

Replace controller 

**No need to change setpoint 

Filter blocking quickly

 

  

Defective cabin sealing 

Perform pressure test procedure & seal leak points as required 

Pre-cleaner failed 

Check operation & replace if necessary 

Display blank

 

 

 

 

 

  

Poor power supply 
  
  

Check mains supply fuse & correct voltage 
Check voltage & 20AMP supply/connections at pin 

1

 @ monitor 

Check earth continuity at controller pin 

12

 

Failed controller 

Replace monitor 

Controller showing 0.0 pressure  

Fresh air filter blocked 

Check filter condition & replace if required. 

Low pressure alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

Door or window open 

Ensure doors & windows securely shut 

Cabin sealing capacity not adequate 

Perform pressure test procedure & rectify cab sealing 

Pressuriser not operating 
  
  
  

Ensure correct voltage 12v or 24v to pressuriser motor pin 

A

 

Check 1.6V - 10V present at motor Pin 

C

 

Check 20A Supply fuse 
Check earth continuity Pin 

B

 

Pressure sense tube blocked 
  
  

Unplug at monitor & ensure clear flow to external of cabin 
Ensure pressure tube fitted correct port 

A

 

**No need to change setpoint 

Pressuriser not working

 

 

 

 

 

 

 

 

 

 

 

Poor power supply 
  
  
  

Check 20A mains fuse & correct voltage 
Ensure adequate wire size & no voltage drop 
Ensure correct voltage 12v or 24v to pressuriser motor pin 

A

 

Check 1.6V - 10V present at motor Pin 

C

 

Poor earth 

Check earth continuity @ motor pin 

B

 

Motor faulty 

Replace TL4M 

Access Codes:

 

Site Access: 7597 

Factory Setup: 6759 

 

Summary of Contents for 409ZX

Page 1: ...10 23 Revision 1 Kit Part Number 700075 409ZX LOADER HEPA H14 Variable Speed Pressuriser INPRESS TS Cabin Display with CO2 Sensor HEPA Return Air Filter 61 7 3276 7833 www breathe safe com au sales b...

Page 2: ...play with Data Recorder HEPA Return Air Filter CONTENTS Installation 1 Safety 2 Critical Parts Maintenance Schedule 3 Operator Guide 4 Specifications Pressuriser 5 Parts List 6 14 Technical Details 15...

Page 3: ...L SAFETY MEASURES BEING TAKEN AND ALL RELEVANT CIRCUIT BREAKER OPENED TO ISOLATE THE CIRCUIT THE AIR FILTRATION SYSTEM MAY HAVE SEVERAL TYPES OF HIGH SPEED ROTATING EQUIPMENT INSTALLED WITH VERY SHARP...

Page 4: ...tion All 500 hour inspection actions Pressuriser s Blower 200002 Replace BRUSHLESS Pressuriser blower CRITICAL PARTS MAINTENANCE SCHEDULE Critical Parts Item Part Number Qty Description Service Interv...

Page 5: ...ioning BreatheSafe recommends OEM air conditioning fan is set at mid speed or greater to circulate air around the breathing zone and minimise CO Acceptable operating range for BreatheSafe fan 10 80 80...

Page 6: ...re FEA Testing Critical components FEA Finite Element Analyst tested in Solid Works Simulation CFD Testing CFD Computational Fluid Dynamics simulations in Flow Works to ensure optimum air flow through...

Page 7: ...ing 200009 7 1 24v DC Brushless VSD Motor TL Fan Blade 200002 8 1 O Ring Seal Kit 2 Parts 200010 9 1 Included in 8 200011 10 1 Wiring Sleeve 200012 11 1 HEPA H14 Filter 500000 12 3 M6 Nyloc Nut 300218...

Page 8: ...r Assembly 1 Per Assy Assembly 2 100062F01 0 Inlet Assembly 1 Charcoal Grey MX83 682 Weld Assy 3 100062F02 0 Fresh Air Door Plate Assembly 1 Charcoal Grey MX83 682 Weld Assy 4 100062M01 0 Monitor Asse...

Page 9: ...ssy 3 100062A04 0 SO2 Rail Assembly 1 Charcoal Grey MX83 682 Weld Assy 4 100062F05 0 SO2 Rail Assy 1 Charcoal Grey MX83 682 Weld Assy 5 100062F06 0 SO2 Mount Plate Assy 1 Charcoal Grey MX83 682 Weld A...

Page 10: ...Part No Rev Description Qty Material Thickness Colour Category 1 100062 F729 0 Inlet Mounting Plate 1 Zan 1 6 Per Assy Part 2 100062 F730 0 Fresh Air Inlet 1 Zan 1 6 Per Assy Part 3 300388 0400 76 3 x...

Page 11: ...FRESH AIR MODULE Item No Part No Rev Description Qty Material Thickness Colour Category 1 100062 F738 0 Fresh Air Inlet Door Plate 1 Mild Steel 3 Per Assy Part 2 300388 0060 76 3 x 1 6 60mm 1 Stainles...

Page 12: ...02 0 Monitor Mount Assy 1 Prt Dwgs Prt Dwgs Charcoal Grey MX83 682 Weld Assy 2 100062M03 0 Clamp Plate Assy 1 Prt Dwgs Prt Dwgs Charcoal Grey MX83 682 Weld Assy 3 100062 M730 0 Spacer 2 Mild Steel 3 C...

Page 13: ...el 4 300848 N A 3 Inch Cobra Neck 3 5 300388 0400 76 3 x 1 6 400mm 1 Stainless Steel 6 200308 0 3 90Deg Short Elbow 2 Silicone 7 200308 0 3 90Deg Short Elbow 3 Silicone 8 300388 0140 76 3 x 1 6 140mm...

Page 14: ...iption Qty Material Thickness Colour Category 1 100062R02 0 Return Air Base Assy 1 Charcoal Grey MX83 682 Weld Assy 2 100062R03 0 R A F Frame Assy 1 Charcoal Grey MX83 682 Weld Assy 3 500016 HEPA Filt...

Page 15: ...the filter towards you and remove Fig 3 6 Clean the filter housing of all debris 7 To replace the filter assemble the components in reverse order Carbon Filter Service Kit 1 Please follow the steps sh...

Page 16: ...OSITIVE PRESSURE INSIDE 3 RJ45 CONNECTOR CO2 SENSOR 4 OVERRIDE TOGGLE SW MAX SPEED Item Destination 1 12 24 VOLT POSITIVE SUPPLY 2 CAN H OPTION 3 CAN L OPTION 4 SERIAL TRANSMIT RS232 5 MOTOR CONTROL V...

Page 17: ...Max Fan on the screen while showing the maximum cabin pressure 6 The MAX cabin pressure should be above 250 Pascals related to the efficiency of cabin seals Please note the minimum result for warranty...

Page 18: ...4 When the product ignites remove the lighter 5 If the product flames up blow out the flame 6 Place the emitter in a non flammable container and place it inside the cabin at floor level and close the...

Page 19: ...n close windows to begin testing 3 Enter the Settings menu via the touch screen button 4 Select and press the System Check button to go to System Test Max Fan 5 Record photograph the maximum cabin pre...

Page 20: ...losure and apply new sealing measures Submission for commissioning procedure as per the diagram below The commissioning images required are ID plate Machine Serial Number Asset Number or Call Sign INP...

Page 21: ...play blank Poor power supply Check mains supply fuse correct voltage Check voltage 20AMP supply connections at pin 1 monitor Check earth continuity at controller pin 12 Failed controller Replace monit...

Page 22: ...RAMETERS Placing the BreatheSafe 200027 unit into Setup mode allows the adjustment of the following parameters Time hours minutes seconds Date day month year Pressure alarm setpoint Preferred cabin pr...

Page 23: ...STARTUP OPTIONS DOOR WINDOW SETTING PRESSURE SETPOINT CHECK RUNTIME DATE TIME CO2 SETTING BACK Pressure Settings PRESSURE UNITS Pascals Alarm Set Point Pressure Set Point Pressure Alarm Delay 20 50 5...

Page 24: ...K Settings SYSTEM CHECK VIEW GRAPH EVENT LOG SITE ACCESS MENU BACK Settings Page 1 NEXT STARTUP OPTIONS DOOR WINDOW SETTING PRESSURE SETPOINT CHECK RUNTIME DATE TIME CO2 SETTING BACK Date Time Setting...

Page 25: ...SENSOR TEMP SETTING BUZZER SETTINGS LOG SETTINGS FACTORY SETUP BACK Settings Page 2 ALARM MUTE RESET ZERO SENSOR TEMP SETTING BUZZER SETTINGS LOG SETTINGS FACTORY SETUP BACK Alarm Buzzer Settings ENAB...

Page 26: ...H EVENT LOG SITE ACCESS MENU BACK Settings Page 1 NEXT STARTUP OPTIONS DOOR WINDOW SETTING PRESSURE SETPOINT CHECK RUNTIME DATE TIME CO2 SETTING BACK CO2 Sensor Alarm Setting DISABLE CO2 SENSOR CO2 AL...

Page 27: ...CK Settings Page 1 NEXT STARTUP OPTIONS DOOR WINDOW SETTING PRESSURE SETPOINT CHECK RUNTIME DATE TIME CO2 SETTING BACK CO2 Sensor Alarm Setting DISABLE CO2 SENSOR CO2 ALARM DELAY SETTING CO2 PRIMARY A...

Page 28: ...e following settings in TeraTerm Serial and choose the correct port connection Hint Click on the COMxx Port with the USB serial Port connection from the drop down menu Example COM 21 This connection m...

Page 29: ...tup Hint From the drop down menu click on the Save Setup Name the file and save it 8 The next time a download is required you may restore the setup and the required COM PORT settings will be loaded re...

Page 30: ...d then press the letter V on the keyboard This procedure will paste the copied data onto that Excel sheet Once that data has been pasted onto the Excel sheet click on DATA on the pull down menu follow...

Page 31: ...the defective goods at our Queensland factory or designated branch Alternatively BreatheSafe may elect to provide new replacement parts BreatheSafe approved repair parts or assembled components needed...

Reviews: