FREE-STANDING
CALISTA
WALL-MOUNTED
CALISTA
TECHNICAL INFORMATION
Type
MT180917FF
Indirect heating
NO
Rated thermal power
9,3 kW
Useful thermal power emitted in the room
9,3 kW
Rendement énergétique (hnom)
75 %
CO (13% O2) (COnom)
0,09 %
CO (13% O2) (COnom)
1063 mg/Nm3
PM (13% O2) (PMnom)
35 mg/Nm3
COG (13% O2) (COVnom)
116 mg/Nm3
NOx (13% O2) (NOxnom)
112 mg/Nm3
CO2
9,2%
Smoke temperature
326°C
Smoke temperature at the nozzle outlet (Tnom)
391°C
Minimum draft - Nominal draft (pnom)
12 Pa
Maximum draft
20 Pa
Fuel
Logs of dry wood 25cm
Recommended wood load
2 logs of 1kg 25 cm lenght split
in ¼
Type of combustion
Intermittent combustion
Refuelling intervals
45min
Mass flow rate of smoke
9 g/s
Smoke discharge diameter
Ø150 mm
Air inlet diameter
Ø80 mm
Mini combustion air inlet section (useful)
100 cm²
Airtight according to EN 16510-1
OUI
If tight, leakage under 10Pa according to EN 16510-1
3m3/h
Mass of appliance only
180 kg
Mass per meter of additional extension
40 kg
Seasonal space heating energy efficiency
65 %
Energy efficiency index
98
Energy efficiency class
A
Minimum distance between the glass pane of the appliance and all combustible materials
1000mm
Minimum distance between the side of the appliance and any combustible materials (dS)
250mm
Minimum distance between the rear of the appliance and any combustible materials (dR)
250mm
Minimum distance between the bottom of the appliance and any combustible materials (dF)
340mm
In case of a wall-mounted appliance, the backing wall must be made of non-combustible material
* The backing wall must be made of non-combustible material and the whole surface of the construction right-of-way must be
insulated.
The insulation must be in the M0, A2s1d0 or A1 reaction-to-fire class and must have a thermal resistance higher than 0.7m².K/W
(measured at 50°C).
The insulation must not deteriorate at temperatures below 400°C (e.g. calcium silicate, rock mineral wool, etc.).
If the backing wall is made of combustible material, it is necessary either:
- to remove the combustible material and to install insulation as described above;
- or to place a non-combustible partition at a distance of least 2cm from the combustible material wall and to ventilate by two
openings (bottom and top).
An insulation layer must then be placed on the partition as described above.
Summary of Contents for CALISTA 917
Page 1: ...CALISTA 917 V04_202112_EN...
Page 4: ...1 FASTENING HARDWARE INSTALLATION FLAT CEILING...
Page 5: ...1 FASTENING HARDWARE INSTALLATION SLOPING ROOF...
Page 13: ...12 2 11 12 INSTALLATION OF DEFLECTORS 12 1...
Page 15: ...ZI de Lh rat 63310 RANDAN T l 0470561600 Fax 0470561689 www bordelet com...