background image

TECHNICAL INFORMATION

It is necessary to comply with all national regulations, 

especially those referring to national and European standards, 

when installing the appliance.

JC BORDELET recommends installing the appliance at a 

minimum distance of 100 mm from non-combustible walls to 

ensure good efficiency of the appliance and facilitate 

assembly.

Since this appliance is airtight, connection to outside air can 

be made either through a triple wall flue duct or by direct 

connection through a connection kit.

For any direct connection to the outside air, it is mandatory to 

ensure that the inlet sections are sufficient according to their 

length and re-routing.

In case of installation of a triple wall flue duct connection, the 

installation instructions and precautions found in the 

Technical Application Document of said duct should be 

complied with, in addition to these instructions. Minimum flue 

height needed for proper appliance operation is 4.5m.

This appliance must not be installed on a smoke duct or an 

air supply serving another appliance.

Exhaust fans in the same room or space as this appliance 

may cause operating problems. (backdraft of smoke, variable 

combustion rate). The compatibility of the appliance with any 

exhaust fan should be ensured.

Exhaust fans have no impact on combustion if the 

combustion air inflow is ducted, the air is drawn from outside 

the building, the door(s) are properly locked, and all the air 

seals are not deteriorated.

The appliance must be suspended according to the 

recommendations of JC BORDELET based on the information 

given and validated by the installer.

It is necessary to provide an access for cleaning the 

appliance, the connection duct and the smoke duct.

Place any air intake grille in such a way that it cannot be 

obstructed.

A minimum distance of 1000 mm between the unit and any 

combustible material should be maintained when the latter is 

pivoting. For all other configurations, refer to the following 

page

For reasons of space, all our appliances are delivered in 

separate components. The assembly must be carried out in 

accordance with this installation manual and according to the 

drawing provided by JC BORDELET after study of the 

installation.

During installation, it is advisable to leave the protection 

devices present on the appliance and to remove them only 

after all the assembly operations are completed.

The actual definitions of certain parts described in this 

manual may change without affecting the installation and/or 

operation.

Summary of Contents for CALISTA 917

Page 1: ...CALISTA 917 V04_202112_EN...

Page 2: ...of smoke variable combustion rate The compatibility of the appliance with any exhaust fan should be ensured Exhaust fans have no impact on combustion if the combustion air inflow is ducted the air is...

Page 3: ...ss A Minimum distance between the glass pane of the appliance and all combustible materials 1000mm Minimum distance between the side of the appliance and any combustible materials dS 250mm Minimum dis...

Page 4: ...1 FASTENING HARDWARE INSTALLATION FLAT CEILING...

Page 5: ...1 FASTENING HARDWARE INSTALLATION SLOPING ROOF...

Page 6: ...ble to the wall type countersunk screws Check the presence of the gasket and the sealing flange behind CALISTA DIRECT CONNECTION WITHOUT TRIPLE WALL FLUE DUCT CONNECTION WITH TRIPLE WALL FLUE DUCT Rem...

Page 7: ...Fixing the lower element on the upper element 3 steel or stainless steel rivets Mounting clamp 3 INSTALLATION OF THE CEILING COVER PLATE 4 INSTALLATION OF FLUE DUCTS...

Page 8: ...astening hardware 3 countersunk head screws M8x20 Perform this same step for installing extensions 3 countersunk head screws M8x20 4m Anti sway system 6 INSTALLATION OF THE ANTI SWAY SYSTEM FREE STAND...

Page 9: ...6 2160mm 7 Assembly of the connection element in the appliance excluding the ducts and extensions installed in the previous steps 200mm 180kg 2120mm 7 CALISTA INSTALLATION ON EXTENSIONS AND DUCTS 7 1...

Page 10: ...7 5 7 4 Fixing the lower element on the upper element 3 steel or stainless steel rivets Mounting clamp Duct connection Fixing the Calista on the extension 3 countersunk head screws M8x20 180kg 360mm...

Page 11: ...4m 8 ADJUSTMENT OF WALL SUPPORTS WALL MOUNTED Fixing the bottom of the appliance to the wall using adjustable supports Screws to be chosen according to wall type 9 ANTI SWAY SYSTEM WALL MOUNTED...

Page 12: ...loser to the nozzle The glass screen cleaning is increased when the register moves closer to the door The bottom glass screen cleaning register s is accessible by removing Calista finishing grid Loose...

Page 13: ...12 2 11 12 INSTALLATION OF DEFLECTORS 12 1...

Page 14: ...t at least two logs with the exception of densified logs Burn wood with humidity 20 Increase the combustion air supply Clear the flue outlet of any disturbing element eg satellite dish etc Raise the c...

Page 15: ...ZI de Lh rat 63310 RANDAN T l 0470561600 Fax 0470561689 www bordelet com...

Reviews: