ENGLISH
USER MANUAL
JB SYSTEMS®
17/87
PARTY BAR
Use the [UP / DOWN] button to select the desired mode:
ON = function activated. When no new information needs to be shown on
the display, the display will turn off. As soon as new information is available
(for example: when you use the remote control to select another mode) the
display will turn on automatically to show you this new information. After a
while, it will turn off again.
OFF = function deactivated. The LED display will be always lit.
Press the [ENTER] button to confirm your setting
o
[TEST] will start up an automatic test mode, so you can check if all the projectors are
working.
o
[rESt] can be used to reset all the settings of the bar to the original factory settings
Just press the [ENTER] button to reset the bar.
MAINTENANCE
Make sure the area below the installation place is free from unwanted persons during servicing.
Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.
The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky o
r particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics.
Clean with a soft cloth using normal glass cleaning products.
Always dry the parts carefully.
Clean the external optics at least once every 30 days.
Clean the internal optics at least every 90 days.
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!
SPECIFICATIONS
Mains Input:
AC 100~240V, 50/60Hz
Fuse:
250V 2A slow blow (20mm glass)
Total Power consumption:
48W
Sound Control:
Internal microphone
DMX connections:
3pin XLR male / female
DMX channels:
3, 5, 6, 9 or 27 channels
PAR LED power:
2 projectors with each 3x 9Watt Tri LEDs
PAR beam angle:
15°
Derby LED power:
2 projectors with each a 3W Red, 3W Green and 3W Blue LED
Laser Power:
30mW 532nm Green, 100mW 650nm Red
Laser radiation class:
3R
Flash LEDs:
4x 1W white LED
Working temperature:
10°C to 40°C
Laser Safety Standard:
EN/IEC 60825-1 2007
Size:
1185x386x110mm
Weight:
Bar= 6.6kg , Bar + Flight-case = 8.35kg
Every information is subject to change without prior notice
You can download the latest version of this user manual on our website: www.jb-systems.eu