40 mm
50 mm
60 mm
80 mm
100 mm
130 mm
130 mm
para manuales - color gris
200 mm
300 mm
Maintenance
Before carrying out maintenance or storage,
always allow the support to cool down.
- Check periodically that the Support is clean,
especially the axes of the sliding guide.
- Use a damp cloth when cleaning. Alcohol
can only be used to clean the metal parts
- Replace any defective or damaged piece.
Use original JBC spare parts only.
- Repairs should only be performed by a JBC
authorized technical service.
4
3
Spring Guide
Clamps
2
1
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm
130 mm
para manuales - color gris
200 mm
300 mm
11
Sliding Guide Axes
Removing the PCB
Push the PCB against the spring guide (1)
until it moves back slightly.
Now the PCB can be taken out of the clamps
at the front (2).
Fast PCB Replacement
Placing another PCB
Position a new PCB inside the slot clamps
of the spring guide. Push it backwards
(against the spring force) until it moves slightly
backwards (3).
Rotate the free side of the PCB downward
and position it in the slot clamps of the front
area (4).
The spring guide automatically locks the PCB
into position.
Spring Guide
Clamps
Maintenance