1
2
5
Retention
Clamps
Cartridge Exchanger
Cartridges are held in place inside the cartridge
exchanger thanks to the retention clamps (5),
with the advantage that the cartridges do not
fall into the exchanger and the cartridge tips are
therefore protected.
The cartridge exchanger of B·IRON stations
works with C210 and C115 cartridges.
Cartridge Retention
The cartridge exchanger saves time and allows to change cartridges safely without switching the
tool off.
Place the cartridge over one of the slots of the
cartridge exchanger and press down (1) until
you hear a click. Then pull the handle out (2)
to remove the cartridge.
1. Removing Cartridges
Cartridge
Exchanger
C115
Cartridge
Place the handle over a cartridge and press the
handle down to insert the cartridge.
2. Inserting Cartridges
C115 Cartridge Retention Area
The holding area of C115 cartridges is delimited
by the two rings at the cartridge shaft (x).
C210 Cartridge Retention Area
The holding area of C210 cartridges goes from
the collar of the tip until the cartridge begins
to widen (x).
C210
Cartridge
x
x
1
2
5
Retention
Clamps
Cartridge Exchanger
Cartridges are held in place inside the cartridge
exchanger thanks to the retention clamps (5),
with the advantage that the cartridges do not
fall into the exchanger and the cartridge tips are
therefore protected.
The cartridge exchanger of B·IRON stations
works with C210 and C115 cartridges.
Cartridge Retention
The cartridge exchanger saves time and allows to change cartridges safely without switching the
tool off.
Place the cartridge over one of the slots of the
cartridge exchanger and press down (1) until
you hear a click. Then pull the handle out (2)
to remove the cartridge.
1. Removing Cartridges
Cartridge
Exchanger
C115
Cartridge
Place the handle over a cartridge and press the
handle down to insert the cartridge.
2. Inserting Cartridges
C115 Cartridge Retention Area
The holding area of C115 cartridges is delimited
by the two rings at the cartridge shaft (x).
C210 Cartridge Retention Area
The holding area of C210 cartridges goes from
the collar of the tip until the cartridge begins
to widen (x).
C210
Cartridge
x
x
Reference Mark
Reference Mark
*Inserting C210 Cartridges
Push the cartridges inside the handle until the
the reference mark is aligned with the edge
of the handle.
Reference Ring
Reference Ring
*Inserting C115 Cartridges
Push the cartridges inside the handle until the
reference ring rests against the sealing plug.
Holes
Depending on the shape of the tip, use the
holes on the sides of the cartridge exchanger
to properly adjust the cartridge.
Important:
Push the cartridge in as far as it
will go, making sure that it is firmly assembled*.
3. Fixing Cartridges
C210 Cartridge Holder
The cartridge holder (4x slots) is used to
store cartridges. It allows to have different
cartridges quickly at hand and it works with
C210 Cartridges.
Cartridge Holder
Slots
C115 Cartridge Adapter
Since C115 cartridges have a smaller diameter
than C210 cartridges, adapters must be used
to store them in the cartridge holder.
These adapters must simply be inserted from
above into the slots of the cartridge holder.
Cartridge
Adapter
Reference Mark
Reference Mark
*Inserting C210 Cartridges
Push the cartridges inside the handle until the
the reference mark is aligned with the edge
of the handle.
Reference Ring
Reference Ring
*Inserting C115 Cartridges
Push the cartridges inside the handle until the
reference ring rests against the sealing plug.
Holes
Depending on the shape of the tip, use the
holes on the sides of the cartridge exchanger
to properly adjust the cartridge.
Important:
Push the cartridge in as far as it
will go, making sure that it is firmly assembled*.
3. Fixing Cartridges
C210 Cartridge Holder
The cartridge holder (4x slots) is used to
store cartridges. It allows to have different
cartridges quickly at hand and it works with
C210 Cartridges.
Cartridge Holder
Slots
C115 Cartridge Adapter
Since C115 cartridges have a smaller diameter
than C210 cartridges, adapters must be used
to store them in the cartridge holder.
These adapters must simply be inserted from
above into the slots of the cartridge holder.
Cartridge
Adapter
12