2
ENGLISH
SPECIFICATIONS
The
AR 5500
is a repair station for desoldering
through-hole components by solder intake.
-
AR 5500
230V
Ref. 5500200
It is supplied with a desoldering iron Advanced
DR
5600
and Advanced
2245
soldering handpiece.
Also all the Advanced soldering handpieces and the
hot tweezers
PA 1200
or
PA 4200
can be connected
to the station.
The station’s components
- Handpiece
2245
Ref. 2245000
with the cartridge
2245-003
Ref. 2245003
- Desoldering iron
DR 5600
Ref. 5600000
with the tip
5600-003
Ref. 5600003
- Soldering iron stand
AD 8200
Ref. 0268200
- Desoldering iron stand
DR 8500
Ref. 0788500
- External desoldering air filter
Ref. 0821830
- Spare filters
Ref. 0781046
- Set of accessories
Ref. 0780593
- Instruction manual
Ref. 0780465
The
A R 5 5 0 0
s t a t i o n h a s t h e f o l l o w i n g
complementary products:
- Handpiece
2010
Ref. 2010000
- Handpiece
2210
Ref. 2210000
- Handpiece
2045
Ref. 2045000
- Micro hot tweezers
PA 1200
Ref. 1200000
- Hot tweezers
PA 4200
Ref. 4200000
Control Unit technical specifications
- Maximum power soldering iron 50W.
- Maximum power desoldering iron 75W.
- Temperature selection of the soldering part:
100 to 371
°
C (
±
5%).
- Temperature selection of the desoldering part:
100 to 371
°
C (
±
5%).
- Station's maximum power: 175W.
- ESD protected housing.
Typical surface resistance: 10
5
-10
11
Ohms/square
- Complies with CE standards on electrical safety,
electromagnetic compatibility and antistatic
protection.
- Equipotential connector is earth connected to the
plug feed of the station.
- Weight of complete unit: 10.6 kg.
- In the SOLD. connector you can only connect
handpieces 2010, 2210, 2045 and 2245 and the
hot tweezers PA 1200 or PA 4200.
- In the DESOLD. connector you can only connect
the desoldering iron DR 5600.
RECOMMENDATIONS FOR USE
For soldering and desoldering
-
Clean the contacts and the printed circuit to
be desoldered of dust or dirt.
-
Preferably select a temperature below 350
°
C.
Excess temperature may cause the printed
circuit tracks to break loose.
-
The tip must be well tinned for good heat
conduction. If it has been inoperative for any
length of time, it should be retinned.
Safety measures
-
Incorrect use of this tool may cause fire.
-
Be cautious when using the tool in places
where inflamable products are stored.
-
Heat can fire up inflamable products even
when they are not at sight.
-
Do not use when the atmosphere is explosive.
-
Place the tool back on its stand in order to let