Alignment
XX
XXXXX
Important.
-
It is essential to insert the cartridge till the end
for a good connection. Take the mark
a s
reference.
Advanced series cartridge
Cartridge is made of the heating element which has the
heating system, temperature sensor and long life tip.
Long-life tip
is basically made of:
1
Copper
2
Iron
3
Chromium
4
Tin plate
2
- Place the handpiece on top of the new cartridge,
press it slightly down and remove the handpiece.
Changing the handpiece's cartridge
With the Advanced system, the cartridge can be
changed quickly, without turning off the station,
so you have two soldering irons in one. Here is
what to do to change the cartridge:
1
- Place the handpiece and remove the cartridge.
3
- Press the cartridge into the opening A, B or C:
A. For straight cartridges 2010 and 2210.
B. For curved cartridges 2010 and 2210.
C. For cartridges 2045 and 2245.
Long-life tip care
Except for the copper core, the rest of metals are
placed galvanically on layers relatively thin, so it
is necessary to avoid the reasons which can
cause its destruction.
To clean the tips, use the sponge included with
the stand and check it is slightly moisted.
O n l y d e i o n i s e d w a t e r ( c a r b a t t e r y w a t e r )
should be used in order to wet the sponge. If
normal water was to be used, it is very likely that
the tip will become dirty due to the salts dissolved
within the water.
To re-tin the soldering tips, we recommend using
the tip tinner/cleaner TT 9400 ref. 9400000.