INTRODUCTION

Each PLATINUM

®

 vacuum pump has been factory tested to guarantee 15 microns  

(25,4000 Microns = 1 Inch of Hg) or better, and listed CFM performance  The serial 

number has been recorded  Complete and mail the enclosed Warranty Registration 

Card or register online at www jbind com within 10 days of purchase to validate 

your warranty  

NOTE: 

PLATINUM

®

 pumps are not to be used on Ammonia or Lithium Bromide  

(salt water) systems  Pump maintenance is the responsibility of the owner 

MOTOR SPECIFICATIONS

Pump and oil must be above 30°F  Line voltage must be equal to motor nameplate 

±10%  Normal operating temperature is approximately 160°F, which is hot to the 

touch  Line voltage and ambient conditions can slightly affect this  Motor has 

automatic resetting thermal overload protection 
The PLATINUM

®

 is designed for continuous duty and will run for extended periods 

without overheating 

OPERATION

The following procedures will prevent oil from being drawn into the pump cartridge 

and creating hard start-up 

Start-up:

 Close both sides of manifold and make connection to vacuum pump or 

auxiliary blank-off equipment  Open one intake port and isolation valve, close gas ballast  

valve and start pump  Make vacuum connections 

(Figure 1)

 

Crack gas ballast valve for the first part of the evacuation procedure  After pump quiets 

down from initial volume of air, close valve and continue evacuating  Failure to close 

valve will result in poor pump performance  Start pump 

Shutdown:

 Close isolation valve and open gas ballast valve all the way  Continue 

running pump for 2-3 seconds  With gas ballast valve still opened, stop pump 

and then close valve  Remove hose connections and cap intakes 

(Figure 1)

  

 

PUMP MAINTENANCE

In order to make the best use of your investment, familiarize yourself with the features 

and operating instructions before starting pump  With routine care and following 

proper maintenance guidelines, your PLATINUM

®

 will give you years of reliable 

service  PLATINUM

®

 pumps are designed for deep vacuum work in air conditioning 

and refrigeration systems 
For a complete overview of proper care and pump maintenance, refer to the 

Keeping 

the Life in your Pump

 section on page 4 

Adding Oil

Step 1:

  Remove filter from pump  Slowly add  

oil until level rises to the top of the oil  

level line  

(Figure 2)

Step 2:

 Replace filter  

If oil level is too low, you will  

hear air out of the exhaust   

If oil level is too high, excess  

oil will be blown out of the exhaust 

IMPORTANT:

 Use oil specifically refined for deep vacuum pumps  Using oil not  

refined for deep vacuum pumps and/or operating with contaminated oil will void 

warranty 
Pump oil should be changed after each use  If system is heavily contaminated,  

oil may have to be changed several times during evacuation  After initial fill up,  

it is best to check oil level with pump running 
After evacuation, oil contains rust forming water and corrosive acids  Drain 

immediately while pump is warm 

Changing Oil

To reach deep vacuum, PLATINUM

®

 pumps need clean, moisture-free oil throughout 

evacuation  Care should be taken to avoid contact on skin and clothing when 

changing oil  Used oil should be disposed of in the DV-T1 TANK Oil Caddy after 

every evacuation while the pump is warm and the oil is thin 

Step 1:

  Place the TANK on a level surface  Unscrew black plug in drain base to open  

Step 2:

  Place vacuum pump in the cradle and drain pump 

Step 3:

   When pump has finished draining, replace black plug  The TANK can hold 

up to five oil changes 

Step 4:

  Close oil drain valve on pump  Remove oil fill plug and fill to top of oil 

level line with BLACK GOLD Pump Oil 

(Figure 2)

  Replace oil fill plug 

Flushing Oil 

Step 1:

  Always drain pump before flushing  If the oil is badly contaminated, flushing 

may be necessary 

Step 2:

  While oil drain is open slowly pour 1/3 to 1/2 cup of BLACK GOLD Pump 

Oil into the intake connection while pump is running  

Step 3:

   Repeat as required until contamination is removed from oil reservoir, pump 

rotors, vanes and housing 

Step 4:

  Dispose of all oil used in flushing of pump 

WARNING: DO NOT START PUMP BEFORE ADDING OIL

Black Gold Pump Oil

Acts as a coolant, lubricant and  

sealant—simultaneously 

 

DV-T1 Tank Pump Oil Caddy

• Change oil between jobs 

• No more mess and spills 

• Easy, convenient, and portable 

• Capacity for five oil changes

Isolation (Blank-Off) valve: Quarter-turn on/off.  

No additional valve needed to isolate system.
When checking pressure rise, slowly turn handle 

counter-clockwise. Pause at 45°. Valve is 

completely closed at 90°.

WARNING: UNIT DRAINED OF OIL FOR SHIPMENT.  

DO NOT OPERATE WITHOUT ADDING OIL.

IMPORTANT

Figure 1

IMPORTANT: OIL LEVEL MUST BE ABOVE

 HALF WAY IN SIGHT GLASS

Figure 2

Summary of Contents for PLATINUM BEAST DV-340N

Page 1: ...ing sealed oil drain valve to prevent leaks 1 HP DC motor with broad operating voltage range Illuminated low profile rocker switch Lift ring for easier hoisting Gas ballast for extended oil life Large diameter oil fill opening Angled easy access 1 4 3 8 or 1 2 intake tee Ergonomic 1 2 NPT break resistant handle Large oil level sight glass Four point stable base Oil mist filter controls exhaust DV ...

Page 2: ...ing Oil Step 1 Remove filter from pump Slowly add oil until level rises to the top of the oil level line Figure 2 Step 2 Replace filter If oil level is too low you will hear air out of the exhaust If oil level is too high excess oil will be blown out of the exhaust IMPORTANT Use oil specifically refined for deep vacuum pumps Using oil not refined for deep vacuum pumps and or operating with contami...

Page 3: ...ilter 19 PR 306 Spacer 20 PR 607 Motor 23 PR 7 Gas ballast valve w o ring 24 P90009 O ring gas ballast valve PLATINUM SERIES REPAIR PARTS ALL MODELS REF NO PART NO DESCRIPTION 26 PR 75 Cushioned handle w lift ring 1 2 NPT 27 PR 22 Oil fill plug w o ring 28 PR 56 Adapter nut w nut o ring 30 PR 501 Cushion and cap 1 2 NPT 3 PR 301 DV 285N Cover assembly w sight glass and drain valve 5 PR 311 Cover s...

Page 4: ...e PROPER START UP AND SHUT DOWN PROCEDURES Step 1 Close blank off valve Step 2 Open gas ballast valve Step 3 Run 2 to 3 seconds Step 4 Shut pump off Step 5 Close gas ballast valve NOTE See previously discussed topic Breaking Vacuum Pump won t pull deep vacuum In order for your pump to pull to a near perfect vacuum oil must be clean and moisture free throughout evacuation A Contaminated oil B Oil l...

Page 5: ... tórica para evitar fugas Motor CC de 1 HP con amplio rango de voltaje de funcionamiento Interruptor basculante iluminado de perfil bajo Cáncamo de elevación que facilita el levantamiento Lastre de gas para una vida prolongada del aceite Abertura de llenado de aceite de diámetro grande Pieza de admisión en T angular de acceso fácil de 1 4 3 8 o 1 2 Mango ergonómico de 1 2 NPT resistente a la rotur...

Page 6: ...hasta que el nivel alcance el tope de la línea Fig 2 Paso 2 vuelva a colocar el filtro Si el nivel de aceite es demasiado bajo escuchará que sale aire por el escape Si el nivel de aceite es demasiado alto el exceso de aceite saldrá expulsado por el escape IMPORTANTE utilice aceite especialmente refinado para bombas de vacío profundo El uso de aceite no refinado para bombas de vacío profundo o el f...

Page 7: ... PR 607 Motor 23 PR 7 Válvula de lastre de gas con junta tórica 24 P90009 Junta tórica válvula de lastre de gas PIEZAS DE REPARACIÓN DE LA SERIE PLATINUM TODOS LOS MODELOS N º DE REF N º DE PIEZA DESCRIPCIÓN 26 PR 75 Mango acolchado con cáncamo de elevación de 1 2 NPT 27 PR 22 Tapón de llenado de aceite con junta tórica 28 PR 56 Tuerca de adaptación con junta tórica de tuerca 30 PR 501 Acolchado y...

Page 8: ...egundos y cierre la válvula de obturación PROCEDIMIENTOS DE ARRANQUE Y APAGADO CORRECTOS Paso 1 cierre la válvula de obturación Paso 2 abra la válvula de lastre de gas Paso 3 deje funcionar por 2 a 3 segundos Paso 4 apague la bomba Paso 5 cierre la válvula de lastre de gas NOTA consulte el tema anteriormente tratado Interrupción del vacío La bomba no genera un vacío profundo Para que su bomba pued...

Page 9: ...nt torique pour éviter les fuites 1 moteur HP c c avec large plage de tension de fonctionnement Interrupteur à bascule éclairé à profil bas Bague de levage pour faciliter le levage Lest de gaz pour longévité accrue de l huile Ouverture de remplissage d huile de grand diamètre Raccord d admission en T coudé facile d accès de 1 4 3 8 ou 1 2 Poignée résistante aux chocs 1 2 NPT ergonomique Grand verr...

Page 10: ...igne le haut de la ligne de niveau d huile figure 2 Étape 2 Remplacer le filtre Si le niveau d huile est trop bas vous entendrez l air sortir de l échappement Si le niveau d huile est trop haut l huile excédentaire sera chassée par l échappement IMPORTANT utiliser de l huile spécialement raffinée pour les pompes à vide profond L emploi d huile non raffinée pour les pompes à vide profond et ou son ...

Page 11: ...07 Moteur 23 PR 7 Vanne de lest de gaz avec joint torique 24 P90009 Joint torique vanne de lest de gaz PIÈCES DE RECHANGE POUR LA SÉRIE PLATINUM TOUS MODÈLES Nº DE RÉF Nº DE PIÈCE DESCRIPTION 26 PR 75 Poignée souple avec bague de levage 1 2 NPT 27 PR 22 Bouchon de remplissage d huile avec joint torique 28 PR 56 Écrou adaptateur avec joint torique d écrou 30 PR 501 Coussinet et capuchon 1 2 NPT 3 P...

Page 12: ...ompe 2 à 3 secondes Étape 4 Éteindre la pompe Étape 5 Fermer la vanne de lest de gaz REMARQUE voir la rubrique précédemment discutée Rupture du vide La pompe refuse de générer un vide profond Pour permettre à votre pompe de générer un vide presque parfait l huile doit être propre et exempte d humidité pendant toute la procédure de génération du vide A Huile contaminée B Niveau d huile trop bas C P...

Reviews: