background image

ENGLISH

OPERATION MANUAL

JB SYSTEMS®

1/30

STR-300

Thank you for buying this JB Systems

®

product. To take full advantage of all possibilities and for your own

safety, please read these operating instructions very carefully before you start using this unit.

FEATURES

This unit is radio-interference suppressed. This product meets the requirements of the current European and
national guidelines. Conformity has been established and the relevant statements and documents have been
deposited by the manufacturer.

This device has been designed to produce decorative effect lighting and is used in light show systems.

Adjustable speed , 1-12 flashes/sec

Possibility to synchronise different units with the Dual 1\4 Jack

Can be used in stand alone mode or with optional remote controller: FL01CX or BF04/D

BEFORE USE

Before you start using this unit, please check if there’s no transportation damage. Should there be any, do
not use the device and consult your dealer first.

Important:

This device left our factory in perfect condition and well packaged. It is absolutely necessary

for the user to strictly follow the safety instructions and warnings in this user manual. Any damage caused
by mishandling is not subject to warranty. The dealer will not accept responsibility for any resulting defects
or problems caused by disregarding this user manual.

Keep this booklet in a safe place for future consultation. If you sell the fixture, be sure to add this user
manual.

Check the contents:

Check that the carton contains the following items:

Operating instructions

STR-300 unit

Hanging bracket

ENGLISH

OPERATION MANUAL

JB SYSTEMS®

2/30

STR-300

SAFETY INSTRUCTIONS:

CAUTION:

To reduce the risk of electric shock, do not remove the top cover.

No user-serviceable parts inside. Refer servicing to qualified service
personnel only.

The lightning flash with arrowhead symbol within the equilateral triangle is intended to alert the use
or the presence of un-insulated “dangerous voltage” within the product’s enclosure that may be of
sufficient magnitude to constitute a risk of electric shock.
The exclamation point within the equilateral triangle is intended to alert the user to the presence of
important operation and maintenance (servicing) instructions in the literature accompanying this
appliance.

This symbol means: indoor use only.

This symbol means: Read instructions.

This symbol determines: the minimum distance from lighted objects. The minimum distance between
light-output and the illuminated surface must be more than 1 meter.

To protect the environment, please try to recycle the packing material as much as possible.

A new light effect sometimes causes some unwanted smoke and/or smell. This is normal and disappears after
some minutes.

To prevent fire or shock hazard, do not expose this appliance to rain or moisture.

To avoid condensation to be formed inside, allow the unit to adapt to the surrounding temperatures when
bringing it into a warm room after transport. Condense sometimes prevents the unit from working at full
performance or may even cause damages.

This unit is for indoor use only.

Don’t place metal objects or spill liquid inside the unit. Electric shock or malfunction may result. If a foreign
object enters the unit, immediately disconnect the mains power.

Locate the fixture in a well ventilated spot, away from any flammable materials and/or liquids. The fixture must
be fixed at least 50cm from surrounding walls.

Don’t cover any ventilation openings as this may result in overheating.

Prevent use in dusty environments and clean the unit regularly.

Keep the unit away from children.

Inexperienced persons should not operate this device.

Maximum save ambient temperature is 40°C. Don’t use this unit at higher ambient temperatures.

The units’ surface temperature may reach up to 85°C. Don’t touch the housing with bare hands during its
operation.

Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging and
servicing.

Allow the device about 10 minutes to cool down before replacing the bulb or start servicing.

Always unplug the unit when it is not used for a longer time or before replacing the bulb or start servicing.

The electrical installation should be carried out by qualified personal only, according to the regulations for
electrical and mechanical safety in your country.

Check that the available voltage is not higher than the one stated on the rear panel of the unit.

The power cord should always be in perfect condition: switch the unit immediately off when the power cord is
squashed or damaged.

Never let the power-cord come into contact with other cables!

This fixture must be earthed to in order comply with safety regulations.

Don’t connect the unit to any dimmer pack.

Always use an appropriate and certified safety cable when installing the unit.

In order to prevent electric shock, do not open the cover. Apart from the lamp and mains fuse there are no user
serviceable parts inside.

Never

repair a fuse or bypass the fuse holder.

Always

replace a damaged fuse with a fuse of the same type

and electrical specifications!

In the event of serious operating problems, stop using the fixture and contact your dealer immediately.

The housing and the lenses must be replaced if they are visibly damaged.

Please use the original packing when the device is to be transported.

Due to safety reasons it is prohibited to make unauthorized modifications to the unit.

Important:

Never look directly into the light source! Don’t use the effect in the presence of persons suffering

from epilepsy.

CAUTION

Summary of Contents for STR-300

Page 1: ...cva Reproduction or publication of the content in any manner without express permission of the publisher is prohibited Operation Manual Mode d emploi Gebruiksaanwijzing Bedienungsanleitung Manual de i...

Page 2: ...t toestel en de gebruikte batterijen op een milieuvriendelijke manier conform de in uw land geldende voorschriften DU ENTSORGUNG DES GER TS Entsorgen Sie das Ger t und die Batterien auf umweltfreundli...

Page 3: ...his is normal and disappears after some minutes To prevent fire or shock hazard do not expose this appliance to rain or moisture To avoid condensation to be formed inside allow the unit to adapt to th...

Page 4: ...ied safety cable that can hold 12times the weight of the device when installing the unit This secondary safety attachment should be installed in a way that no part of the installation can drop more th...

Page 5: ...arations et documents correspondants ont t d pos s par le fabricant Cet appareil a t con u pour la production d effets lumi re d coratifs et est utilis dans des spectacles lumineux Vitesse r glable de...

Page 6: ...ou de remplacement des ampoules ne pas ouvrir l installation dans les 15 minutes suivant la fin de l utilisation jusqu ce que l appareil ait refroidi D branchez syst matiquement l unit avant toute op...

Page 7: ...ne de ses pi ces doivent tre bien fix es et non corrod es Les niches fixations et structures de support plafond poutres suspensions doivent tre totalement intactes sans aucune d formation Lorsqu une l...

Page 8: ...d en elektrische schokken te voorkomen Om de vorming van condensatie binnenin te voorkomen laat het apparaat aan de omgevingstemperatuur wennen wanneer het na het transport naar een warm vertrek is ov...

Page 9: ...controleren dat de minimum puntbelasting van de installatieplaats 10 keer het gewicht van het toestel bedraagt Gebruik bij het installeren van het toestel altijd een gewaarmerkte veiligheidskabel die...

Page 10: ...en haben Bitte lesen sie diese Bedienungsanleitung sorgf ltig vor der Inbetriebnahme durch zur vollen Aussch pfung der M glichkeiten die dieses Ger t bietet sowie zu Ihrer eigenen Sicherheit EIGENSCHA...

Page 11: ...3 Muttern der Schutzabdeckung ab 4 Nehmen Sie die Schutzabdeckung ab 5 Auf der Innenseite k nnen Sie die Lampenfassung sehen Gebrauchtes Leuchtmittel herausziehen An der Fassung festhalten wenn ein n...

Page 12: ...en und rostfrei sein Geh use Befestigungsmaterialien und Aufh ngungen Decke Balken abgeh ngte Decken d rfen keine Anzeichen von Verformung zeigen Ist die Optik sichtbar besch digt Spr nge oder tiefe K...

Page 13: ...arece despu s de algunos minutos Para evitar incendios o riesgos de descarga no exponga la unidad a la lluvia o a la humedad Para evitar que se forme condensaci n en el interior deje que la unidad se...

Page 14: ...instale la unidad Este accesorio de seguridad secundario debe instalarse de forma que ninguna pieza de la instalaci n pueda caerse m s 20 cm si falla el accesorio principal El dispositivo debe fijars...

Page 15: ...STICAS Esta unidade est protegida contra interfer ncias r dio Este produto cumpre as exig ncias impostas pelas presentes directivas nacionais e europeias A conformidade deste produto foi comprovada e...

Page 16: ...sempre a unidade da corrente antes de efectuar a manuten o Utilize sempre pe as suplentes com as mesmas caracter sticas l mpadas fus veis etc Utilize unicamente pe as originais 1 Desligue a unidade e...

Page 17: ...e e n o poder o estar corro dos A cobertura da unidade os pontos de fixa o e as reas de instala o tecto arma o etc n o dever o apresentar qualquer deforma o Caso uma lente apresente danos vis veis com...

Reviews: