MAINTENANCE
•
Make sure the area below the installation place is free from unwanted persons during servicing.
•
Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
•
All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
•
Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
•
When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
•
The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
•
In order to protect the device from overheat the cooling fans and ventilation openings should be cleaned
monthly.
•
The interior of the device should be cleaned annually by experienced service people.
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel only!
SPECIFICATIONS
This unit is radio-interference suppressed. This product meets the requirements of the current European and
national guidelines. Conformity has been established and the relevant statements and documents have been
deposited by the manufacturer.
Mains Input:
AC 100~240V, 50/60Hz
Fuse:
250V 1.6A slow blow (20mm glass)
Total Power consumption:
65W
Sound Control:
Internal microphone
DMX connections:
3pin XLR male / female
DMX channels:
2 or 10 channels
DMX starting address:
001
503/511 (10 channel or 2 channel mode)
Laser Power:
50mW Green CW laser (
λ = 532nm)
2 x 150mW Red CW laser (
λ = 650nm)
500mW Blue CW laser (
λ = 450nm)
Laser radiation class:
Class 3B
Laser Safety Standard:
EN 60825-1:2014 for Laser Safety
Size (WxHxD):
53,7cm x 26,8cm x 17cm
Weight:
5.05kg