JB Systems MULTIBEAM LASER Operation Manual Download Page 11

ENGLISH 

 

USER MANUAL 

 

 
JB SYSTEMS

®

 

9/9 

MULTIBEAM LASER 

MAINTENANCE

 

  Make sure the area below the installation place is free from unwanted persons during servicing. 

  Switch off the unit, unplug the mains cable and wait until the unit has been cooled down. 

During inspection the following points should be checked: 

  All screws used for installing the device and any of its parts should be tightly fastened  and may not be 

corroded. 

  Housings, fixations and installations spots (ceiling, truss, suspensions) should  be  totally free from any 

deformation. 

  When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced. 

  The mains cables must be in impeccable condition and should be replaced immediately when even a 

small problem is detected. 

  In order to protect the device from overheat the cooling fans and ventilation openings should be cleaned 

monthly. 

  The interior of the device should be cleaned annually by experienced service people. 

Attention: We strongly recommend internal cleaning to be carried out by qualified personnel only! 
 

SPECIFICATIONS 

This unit is radio-interference suppressed. This product meets the requirements of the current European and 
national guidelines. Conformity has been established and the relevant statements and documents have been 
deposited by the manufacturer. 

 
Mains Input: 

AC 100~240V, 50/60Hz  

Fuse: 

250V 1.6A slow blow (20mm glass) 

Total Power consumption:

 

65W 

Sound Control: 

Internal microphone 

DMX connections: 

3pin XLR male / female

 

 

DMX channels: 

2 or 10 channels 

DMX starting address:

 

001 

 503/511 (10 channel or 2 channel mode)  

Laser Power:

 

50mW Green CW laser (

λ = 532nm) 

 

 

2 x 150mW Red CW laser (

λ = 650nm) 

 

 

500mW Blue CW laser (

λ = 450nm) 

Laser radiation class:

 

Class 3B 

Laser Safety Standard:

 

EN 60825-1:2014 for Laser Safety 

Size (WxHxD):

 

53,7cm x 26,8cm x 17cm  

Weight:

 

5.05kg 

 

 

 

Every information is subject to change without prior notice. 

You can download the latest version of this user manual on our website:

 

www.jb-systems.eu

 

Summary of Contents for MULTIBEAM LASER

Page 1: ......

Page 2: ......

Page 3: ... for wireless DMX just plug in an optional WTR DMX DONGLE Briteq order code 4645 SAFETY FIRST Class 3B lasers more than 500mW output can damage the human eye very badly so never buy such high power laser without checking if it passed the severe laser safety tests This laser complies to the European EN 60825 1 2014 for Laser Safety It is equipped with extra safety measures like Interlock connection...

Page 4: ...ation openings as this may result in overheating Prevent use in dusty environments and clean the unit regularly Keep the unit away from children Inexperienced persons should not operate this device Maximum save ambient temperature is 40 C Don t use this unit at higher ambient temperatures Make sure the area below the installation place is free from unwanted persons during rigging de rigging and se...

Page 5: ...laser beam to people or animals and never leave this device running unattended This laser may only be used for shows The operation of this class 3B show laser is only allowed if it is done by a professional operator Depending on the classification operating a laser product can produce laser radiation that may cause permanent eye damage and or skin damage The legal instructions for using a laser pr...

Page 6: ... optional WTR DMX DONGLE from BRITEQ and you will get wireless DMX Moreover you will be able to connect other DMX controlled equipment to the DMX output so you can share the wireless DMX function with all connected units No extra settings to be made in the setup menu just follow the procedure in the user manual supplied with the WTR DMX DONGLE from BRITEQ The separate WTR DMX DONGLE is available f...

Page 7: ... be seated Before rigging make sure that the installation area can hold a minimum point load of 10times the device s weight Always use a certified safety cable that can hold 12 times the weight of the device when installing the unit This secondary safety attachment should be installed in a way that no part of the installation can drop more than 20cm if the main attachment fails The device should b...

Page 8: ...show 2 STANDALONE MODE USING THE BUILD IN PROGRAMS MUSIC CONTROLLED Press the MENU button until the display shows Sn1 Press the ENTER button to confirm your choice Put on some music and adjust the MUSIC SENSITIVITY knob 18 until the laser works nicely to the rhythm of the music Note When no music is detected the laser output will be shut off blackout 3 MASTER SLAVE MODE You can connect several MUL...

Page 9: ...he different channels Some more information on DMX512 The DMX protocol is a widely used high speed signal to control intelligent light equipment You need to daisy chain your DMX controller and all the connected light effects with a good quality XLR M F balanced cable To prevent strange behavior of the light effects due to interferences you must use a 90Ω to 120Ω terminator at the end of the chain ...

Page 10: ...ling CH 8 000 127 0 359 degree fixed Z axis rotate 128 191 Clockwise rotating 128 255 Anticlockwise rotating CH 9 000 127 128 different fixed position on X 128 191 Clockwise moving 128 255 Anticlockwise moving CH 10 000 127 128 different fixed position on Y 128 191 Clockwise moving 128 255 Anticlockwise moving 5 IR Remote control The laser can also be controlled by the IR remote control Press the ...

Page 11: ...ior of the device should be cleaned annually by experienced service people Attention We strongly recommend internal cleaning to be carried out by qualified personnel only SPECIFICATIONS This unit is radio interference suppressed This product meets the requirements of the current European and national guidelines Conformity has been established and the relevant statements and documents have been dep...

Page 12: ......

Reviews: