JB Systems LIVESET 2 Operation Manual Download Page 4

ENGLISH 

USER MANUAL 

 

 
JB SYSTEMS

®

 

2/13 

LIVESET 2 

 

  To protect the environment, please try to recycle the packing material as much as possible. 

  To prevent fire or shock hazard, do not expose this appliance to rain or moisture. 

  To avoid condensation to be formed inside, allow the unit to adapt to the surrounding temperatures when 

bringing  it  into  a  warm  room  after  transport.  Condense  sometimes  prevents  the  unit  from  working  at  full 
performance or may even cause damages. 

  This unit is for indoor use only.  

 

Don’t place metal objects or spill liquid inside the unit. Electric shock or malfunction may result. If a foreign 
object enters the unit, immediately disconnect the mains power. 

  Locate the fixture in a well ventilated spot, away from any flammable materials and/or liquids. The fixture 

must be fixed at least 50cm from surrounding walls. 

 

Don’t cover any ventilation openings as this may result in overheating.  

  Prevent use in dusty environments and clean the unit regularly. 

  Keep the unit away from children. 

  Inexperienced persons should not operate this device. 

  Maximum safe ambient temperature is 40

°C. Don’t use this unit at higher ambient temperatures. 

  Make  sure  the  area  below  the  installation  place  is  free  from  unwanted  persons  during  rigging,  de-rigging 

and servicing. 

  Allow the device about 10 minutes to cool down before to start servicing. 

  Always unplug the unit when it is not used for a longer time or before to start servicing. 

  The electrical installation should be carried out by qualified personal only, according to the regulations for 

electrical and mechanical safety in your country. 

  Check that the available voltage is not higher than the one stated on the unit. 

  The power cord should always be in perfect condition. Switch the unit immediately off when the power cord 

is squashed or damaged. It must be replaced  by the  manufacturer, its service agent or similarly qualified 
persons in order to avoid a hazard. 

  Never let the power-cord come into contact with other cables! 

  This fixture must be earthed in order to comply with safety regulations. 

 

Don’t connect the unit to any dimmer pack. 

  Always use an appropriate and certified safety cable when installing the unit. 

  In order to prevent electric shock, do not open the cover. There are no user serviceable parts inside. 

 

Never

 repair a fuse  or bypass the fuse holder. 

Always

 replace a damaged fuse  with a fuse of the same 

type and electrical specifications! 

  In the event of serious operating problems, stop using the fixture and contact your dealer immediately. 

  The housing and the lenses must be replaced if they are visibly damaged. 

  Please use the original packing when the device is to be transported. 

  Due to safety reasons it is prohibited to make unauthorized modifications to the unit. 

Important: 

Never look directly in

to the light source! Don’t use the effect in the presence of persons suffering 

from epilepsy. 

 

The  lightning flash with arrowhead symbol within the  equilateral triangle  is intended to alert  the 
use or the presence of un-ins

ulated “dangerous voltage” within the product’s enclosure that may 

be of sufficient magnitude to constitute a risk of electric shock. 

 

The exclamation point within the equilateral triangle is intended to alert the user to the presence 
of  important  operation  and  maintenance  (servicing)  instructions  in  the  literature  accompanying 
this appliance. 

 

This symbol means: indoor use only

 

 

This symbol means: Read instructions

 

 

This symbol means: Safety Class I appliance 

 

This  symbol  determines:  the  minimum  distance  from  lighted  objects.  The  minimum  distance 
between light-output and the illuminated surface must be more than x meters 

 

The device is not suitable for direct mounting on normally flammable surfaces. (suitable only for 
mounting on non-combustible surfaces) 

 

CAUTION: 

Do not stare at operating lamp.  

May be harmful to the eyes. 

Summary of Contents for LIVESET 2

Page 1: ......

Page 2: ......

Page 3: ...es needed Excellent built in programs for wonderful ever changing light shows Special USB connection for use with an optionally available Wireless DMX dongle LED display for easy menu navigation and setup BEFORE USE Before you start using this unit please check if there s no transportation damage Should there be any do not use the device and consult your dealer first Important This device left our...

Page 4: ...t be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Never let the power cord come into contact with other cables This fixture must be earthed in order to comply with safety regulations Don t connect the unit to any dimmer pack Always use an appropriate and certified safety cable when installing the unit In order to prevent electric shock do...

Page 5: ...controlled shows to the beat of the music 9 SENSITIVITY KNOB turn this knob anti clockwise to decrease the sensitivity or turn it clockwise to increase the sensitivity of the integrated microphone 10 DISPLAY shows all the necessary information about settings and working modes 11 CONTROL PANEL Used to select the different functions of the bar see further to learn how to operate the unit OVERHEAD RI...

Page 6: ...01 slow to S 99 fast Press ENTER to confirm your setting If you want a program where the 4 projectors do exactly the same you can enable the SYNC mode Press the MENU button until the display shows SyN Press the ENTER button to enter the mode Use the UP or DOWN buttons to select Sy A Press the ENTER button to enter the mode Now you can use the UP or DOWN buttons to select the desired speed Press th...

Page 7: ... all work synchronously you can work in the so called master slave mode To do this just daisy chain all the bars and make the settings of the desired automatic or sound controlled program in the first bar of the chain see description above This bar is called the Master unit Note to send out the information from the master to the slaves you also have to set the master unit in MASTER MODE Press the ...

Page 8: ... CONTROLLED VIA DMX The LIVESET can be controlled by any standard DMX controller in several different DMX modes Connect the DMX input of the unit to the DMX output of the previous unit in the chain or directly to the DMX output of your controller Press the MENU button until the display shows DMH Press the ENTER button to enter this option The actual DMX address is shown on the display Press the EN...

Page 9: ...possible address setup could be unit1 001 unit2 005 unit3 009 unit4 013 etc 1 CHANNEL DMX CONFIGURATION DMX Channel DMX value function remarks 1 000 009 Blackout Automatic shows Speed can be controlled from Slow to Fast 010 072 Auto Par 073 132 Auto Flash Led 133 195 Auto Mix 196 215 Sound Par Sound controlled shows 216 235 Sound Flash Led 236 255 Sound Mix 4 CHANNEL DMX CONFIGURATION DMX Channel ...

Page 10: ...ol 1 000 255 Red 0 100 2 000 255 Green 3 000 255 Blue RGB Projector 2 control 4 000 255 Red 0 100 5 000 255 Green 6 000 255 Blue RGB Projector 3 control 7 000 255 Red 0 100 8 000 255 Green 9 000 255 Blue RGB Projector 4 control 10 000 255 Red 0 100 11 000 255 Green 12 000 255 Blue RGB Main Dimmer 13 000 255 Intensity 0 100 RGB Strobe 14 000 009 No Strobe 010 083 Pulse Closed Slow to Fast 084 163 P...

Page 11: ...55 Blue RGB Projector 3 control 7 000 255 Red 0 100 8 000 255 Green 9 000 255 Blue RGB Projector 4 control 10 000 255 Red 0 100 11 000 255 Green 12 000 255 Blue Main Dimmer 13 000 255 Intensity 0 100 RGB Strobe 14 000 009 No Strobe 010 083 Pulse Closed 084 163 Pulse Open 164 243 Strobe Slow to Fast 244 255 Sound Strobe Sound controlled modulator effect White LED Strobe 15 000 255 White Strobe Slow...

Page 12: ...DMX output of your controller Press the MENU button until the display shows DMH Press the ENTER button to enter this option The actual DMX address is shown on the display Press the ENTER button again to access the DMX settings You can now change the DMX mode Use the UP DOWN buttons to select the DMX mode LC02 Press the ENTER button to confirm your choice Now you can use the UP DOWN buttons to set ...

Page 13: ...er 0 100 11 Blue projector 3 000 255 Dimmer 0 100 12 Dim Strobe Music Mode projector 3 000 007 Blackout 008 190 Master Dimmer 0 100 191 200 Automatic Sound controlled Mode 201 247 Strobe speed slow to fast 248 255 Maximum Master dimmer level 13 Red projector 4 000 255 Dimmer 0 100 14 Green projector 4 000 255 Dimmer 0 100 15 Blue projector 4 000 255 Dimmer 0 100 16 Dim Strobe Music Mode projector ...

Page 14: ...Function 1 Red projector 1 000 255 Dimmer 0 100 2 Green projector 1 000 255 Dimmer 0 100 3 Blue projector 1 000 255 Dimmer 0 100 4 to 8 NOT USED No function 9 Red projector 2 000 255 Dimmer 0 100 10 Green projector 2 000 255 Dimmer 0 100 11 Blue projector 2 000 255 Dimmer 0 100 12 to 16 NOT USED No function 17 Red projector 3 000 255 Dimmer 0 100 18 Green projector 3 000 255 Dimmer 0 100 19 Blue p...

Page 15: ...iodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit s optics Clean with a soft cloth using normal glass cleaning products Always dry the parts carefully Attention We strongly recommend internal cleaning to be carried out by qualified personnel ...

Page 16: ......

Reviews: