ENGLISH
OPERATION MANUAL
JB SYSTEMS®
8/57
MICRO/MINI LED MANAGER
the 3
rd
has address 210, …, until the 16
th
Micro / Mini LED Manager who automatically receives
start address 262.
You just programmed 16 Micro / Mini LED Managers, this took you about 10seconds!!!
Remark:
you can mix the units with other DMX-
effects that don’t have the automatic DMX-
addressing option. In that case you still have to set the DMX-addresses of these DMX-effects
manually! You can also mix the Micro / Mini LED Managers with other JB Systems LED products
that have the auto DMX-feature. They will also automatically receive their DMX-addresses.
C. Setting DMX-addresses using the DIP switches:
This is the traditional addressing method, this method should be used when used with the LED
WALL DIMMER. The first 9 DIP-switches correspond to a certain DMX-value:
You can combine the values of these switches to obtain any starting address between 1 and 512:
Begin address = 01
switch 1=ON
values: 1
Begin address = 05
switch 1+3=ON
values: 1+4 = 5
Begin address = 09
switch 1+4=ON
values: 1+8 = 9
Begin address = 13
switch 1+3+4=ON
values: 1+4+8 = 13
…
Begin address = 62
switch 2+3+4+5+6=ON
values: 2+4+8+16+32 = 62
OPERATING INSTRUCTIONS
A. Standalone 1unit:
Connect the LED projectors to the Micro / Mini LED Manager as indicated in the previous chapters.
Switch the unit on and refer to the
chapter “DIP SWITCH SETTINGS” to make yourself familiar with
the various functions of the faders and buttons.
B. Two or more units in master/slave setup:
Connect the LED projectors to the Micro / Mini LED Managers as indicated in the previous chapters.
Connect the units with each other as explained in the chapter about electrical installations.
Switch the Micro / Mini LED Managers on. You can only use the controls on the master unit, the
controls on the slaves are disabled. Refer to the
chapter “DIP SWITCH SETTINGS” to make yourself
familiar with the various functions of the faders and buttons on the master unit.
C. Connect the optional LEDCON-02 for remote control:
In most cases the MICRO / MINI LED MANAGER will be installed on a wall, close to the LED-projectors.
If you want to have easy access to its functions, you can connect the LEDCON-02 remote controller to
the (first) Micro / Mini LED Manager. The other connections are identical to those of the standalone or
master/slave setups.
Don’t forget to perform the automatic addressing on the LEDCON-02!!!
D. Controlled by universal DMX-controller:
Connect the LED projectors to the Micro / Mini LED Manager(s) as indicated in the previous chapters.
Connect the Micro / Mini LED Manager(s) with all other DMX-appliances in the DMX-chain.
Switch all units on and set the proper DMX-addresses. (
don’t forget to set DIP-switch 10 to OFF)
Switch your universal DMX-controller on and refer to the DMX chart below to control the connected
Micro / Mini LED Managers:
DIP
#1
#2
#3
#4
#5
#6
#7
#8
#9
Value
1
2
4
8
16
32
64
128
256