6.7 INFO-menu
The Info menu informs you about the respective software, the fixture id, about the total operating
time and the different temperatures of the spotlight. The first two menu items in the Info area are
the software version and the fixture ID, whereby the software version is an important source of
information for our service requests, the fixture ID is less important source of internal information.
Under the menu item TOT OPERATE TIME the complete operating time of the headlight is
displayed. The menu item TOT LAMP TIME provides information about the pure operating time
of the LED module. TOT BAT CHARGE TIME shows the complete charging time of the battery
(battery backup). The TOT OPERATE TIME and the TOT BAT CHARGE TIME can not be deleted!
The following temperatures are also displayed:
TEMP BASE LCD
, the temperature on the display board
TEMP BASE PS
, the temperature of the power supply unit
TEMP HEAD MAIN
, the temperature of the head board
TEMP HEAD DRV
, the temperature of the LED driver board
TEMP HEAD LED
, the temperature of the LED module
TEMP HEAD AMBIENT
, the temperature in the head next to the air inlet (ambient temperature)
Both the current temperature and the maximum temperature are displayed. The maximum
temperatures can be individually deleted.
6.8 Shortcuts - quick access
ESC + DOWN
Pressing the ESC and DOWN buttons in the main menu will log the fixture off the programmed
Lumen Radio Wireless transmitter. The fixture is now ready to be logged in another transmitter.
ENTER + UP
If ENTER + UP is pressed in the main screen, the screen orientation is rotated by 180 °.
ENTER + ESC
By pressing the ENTER and ESC key, the fixture is locked for user input -> LOCKED. ESC and
ENTER release the lock again!
Operation via master-slave function:
Connect the P9 Beamspot via DMX lines and activate the REMOTE menu item for all slave
devices. To do this, navigate in the STANDALONE menu to the REMOTE sub-menu. Activate the
REMOTE function by pressing and holding “ENTER”, and also pressing “ESC”. The spotlight is
in slave mode when the display shows the status REMOTE INACTIVE or REMOTE ACTIVE.
REMOTE INACTIVE: The P9 Beamspot is in slave mode but does not receive a DMX signal.
REMOTE ACTIVE: The P9 Beamspot is in slave mode and receives a DMX signal.
The master device is programmed via the MODIFY menu item and started via RUN (press
and hold “ENTER” and also press “ESC”).