- 15 -
P9
Display illumination as function display
The display illumination remains switched off during the reset. Slowly flashing display illumination
when "JB-Lighting" is displayed means no DMX signal is present.
A very rapidly flashing display illumination when "JB-Lighting" is displayed means that a new
error has been stored in the "ERROR LIST", also an error message in the display (e.g. *PAN
TIMEOUT) indicates this current error. This error occurs during this reset or in the operation
before. This error is now automatically set to "read", but remains in the "ERROR LIST".
A rapidly flashing display illumination shows an error in the "ERROR LIST" is still in it but has
already been confirmed or was automatically confirmed. Only when the error has been deleted
from the ERROR LIST does the P9 Beamspot start again without error signalling.
If errors occur again and again contact the dealer / distributor or our service department.
If the P9 Beamspot receives a DMX signal, the display illumination goes out after 30 seconds.
Further settings for the display illumination see page 20 BACKLIGHT MODE.
DMX addressing
In the main menu, the DMX address can be set directly by pressing the up/down keys.
Display operation via battery backup
By pressing the left button below the display, the configuration battery operation of the headlamp
is activated, so the headlamp can be configured without power. It is possible to configure all the
settings displayed by the menu, for example the DMX address can be set.
Summary of Contents for P9 Beamspot
Page 1: ...Operating instructions Version 1 04 Software 1 0 0 P9 Beamspot...
Page 2: ...02 P9...
Page 4: ...04 P9...
Page 41: ...41 P9...
Page 42: ...42 P9...
Page 43: ...43 P9...