Troubleshoo

ting

 

If your 

RCL700

 stops opera

ti

ng, please check for the following condi

ti

ons: 

1.

Check the ba

tt

eries in the  wireless remote.

2.

The inrush current for an incandescent lamp is typically ten to 

fift

een 

ti

mes the opera

ti

ng

current and an HID switching power supply inrush current can be even greater. This high 

inrush current can cause a severe voltage drop if the power feed wires are long, under size or 

the power supply is weak. This may cause the receiver circuit to enter a low voltage shutdown 

state. It is recommended to only turn on the lights while the vehicle is running. The power to 

the 

RCL700

 needs to be cycled o

 and back on to reset the shutdown circuit. 

3.

The motor control circuit is overcurrent and over temperature protected in the event the light 

is jammed against an imovable object. The power to the 

RCL700

 will need to be cycled o

and back on to reset the overcurrent/over temperature circuit.