background image

 

- 6 - 

5.  Fix the opener to the ceiling joist or suitable support using fasteners suitable for the fixing material (not supplied) 

and observe the fastener manufacturers guidelines, uses and ratings.     

6.  Fix the door bracket(A) to the top edge of the door in the middle and under the wall bracket using suitable fasteners 

(not supplied) 

7.  Connect the bent arm(G) to the door bracket using the 

Φ

8x25 axle pin and cotter pin as shown in Fig.5. 

8.  Install  the  shuttle(D)  to  the  track  using  the  4x  M6x20  screws  supplied  (Fig.6),  tie  the  clutch  cord.  Connect  the 

straight  arm(H)  to  the  clutch  using  the 

Φ

8x25  axle  pin  as  shown  in  Fig.5.  Affix  manual  release  procedure 

instruction card to clutch cord/manual release cord. 

9.  Connect the bent arm and straight arm using M8 outer hexagon bolts and nuts supplied (before connecting, adjust 

to a suitable length) 

10.  Release the clutch, try to open and close the door by hand. Make sure there is no contact between door panel and 

track. 

11.  Connect the opener to power. 

Notice

: Make sure the opener’s voltage is in accordance with the local voltage. Connect the opener to a properly 

earthed power supply. 

 

 

 

Track Assembly 

 Only required for segmented rails 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Confirm  the  type  of  segmented  rail 
you have according to Fig7. 

Skip  this  step  if  you  have  a  1piece 
rail. 

Fig.7 

Install the rails according the steps 
in Fig8: 

A. Connect the rails by the sleeve; 

B. Follow the steps in the picture to 
connect the rails 

C. Move  the  pulley  to  the  top  end 
of  the  rail  after  the  rails  are 
connected 

D. Stretch  the  screw  bolt  of  the 

pulley  into  the  hole  on  the  rail. 

Install  the  spring,  washer,  and 

adjusting  nut.  Adjust  the  nut  to  a 

suitable position, the installation of 

the rail is complete. 

Fig.8 

2 IN 1 

4 IN 1 

3 IN 1 

Summary of Contents for 1000N

Page 1: ...ore installation and use The installation of your new door opener should be carried out by a technically qualified person Attempting to install or repair the door opener without suitable technical qualification may result in severe personal injury death and or property damage TM ...

Page 2: ...ck assembly optional 6 Battery backup assembly optional 7 Basic function settings 7 Special functions optional parts introduction and application 11 Manual disengagement 12 Maintenance 13 Final notes 13 Important information for the user 13 Packing list 14 Technical specifications 14 Common faults solutions 15 Warranty information 14 Warranty form 14 ...

Page 3: ...thout observing all the applicable safety standards will be responsible for any damage injury expense or claim as a result of failure to install the system correctly and in accordance with the relevant safety standards For additional safety we recommend the inclusion of a Photo Beam System Although the opener incorporates a pressure sensitive Safety Obstruction Force system the addition of a Photo...

Page 4: ...h a warning sign advising to keep children away from a moving garage door having a height of at least 60 mm Periodically check that this warning is still in place This garage door opener is supplied with an information card that should be attached to the manual release cord detailing the manual release procedure This garage door opener should be disconnected from its power source during cleaning a...

Page 5: ...ing function so the garage door can still be locked manually in the event of a power outage 12 1200Nm lifting force 13 Safety reverse function The door will reverse to the fully open position when encountering a solid obstacle on closing cycle and stop when encountering excess resistance on the open cycle These values are adjustable from the menu 14 Backup battery interface available in case of po...

Page 6: ...ances Important note It is thoroughly recommended that the installation of a garage door opener be carried out by a trained Technician DIY is an option but proceed at your own risk Installation 1 Read the instructions carefully 2 Make sure the door structure is solid and suitable to be motor driven 3 Make sure the door runs smoothly in manual operation before fitting an automatic opener 4 The door...

Page 7: ...er falling and may cause serious damage and or personal injury Installation steel track 1 Fix the wall bracket B to the wall 2cm 15cm above the torsion shaft or spring and central to the door 2 Fix the steel track to the wall bracket using axis pin Φ8x80 C and cotter pin Fig 5 3 Fix garage door opener to the track using 2 x U brackets supplied E Then fasten using M6 nuts x4 supplied 4 Fix the hang...

Page 8: ...r hexagon bolts and nuts supplied before connecting adjust to a suitable length 10 Release the clutch try to open and close the door by hand Make sure there is no contact between door panel and track 11 Connect the opener to power Notice Make sure the opener s voltage is in accordance with the local voltage Connect the opener to a properly earthed power supply Track Assembly Only required for segm...

Page 9: ... illuminated Fig A Press a preferred button on transmitter once the LED dot will extinguish press the same button on the transmitter again The transmitter is now coded into the receiver Repeat the above steps to code more transmitters The receiver has the capacity to store 20 transmitters If the LED display flashes F and returns to standby mode after you have pressed the CODE button this indicates...

Page 10: ...the position by momentarily pressing the UP and DOWN buttons to determine the final close limit position then press SET If the opener stops and displays H or C this indicates there s no hall signal or the opener is overloaded Call a Service Technician The opener will now operate a cycle automatically to remember the limit positions and the original opening closing force then return to standby mode...

Page 11: ...y 1 minute The auto close function will be turned off when the LED displays 0 Press SET button to confirm the opener returns to standby mode The auto close function is only be available when the door is fully open and the photo beam function is on The default setting is o Press and hold SET button for 3 seconds until the LED flashes 1 Press UP button until the LED flashes 3 press SET button The di...

Page 12: ...urns to standby mode When the lock door function is on and the door is fully closed the opener will lock the door automatically The door can only be opened by a transmitter after unlocking by the lock key S2 on the transmitter If not unlocked by the S2 button on the transmitter the light will flash twice when pressing the open key on the transmitter Press and hold SET button for 3 seconds until th...

Page 13: ...s for this function and provide 24v 35v flashing light voltage Connect the flashing light with DC 24v 28v current 100mA When using AC 220V power flashing lights please match an adapter and wiring as required Fig 13 Pass door SD protection optional This function ensures that the door can t be opened unless a small pass door is closed Connect according to Fig 14 Fig 11 Fig 12 ...

Page 14: ...ith the manual release cord To re engage the shuttle simply flick the manual release cord backwards so that the attaching arm is facing towards the opener head unit then run opener in automatic mode or move door by hand until the trolley engages in the chain shuttle spring loaded In some situations where no other access to the garage is possible it is recommended that an external disengagement dev...

Page 15: ...nly to be used by technical persons who are qualified to carry out the installation It is important for the installer to show their clients correct operation of the opener including the procedure for manual disengagement Inform the owner about the need of regular maintenance especially regarding a regular check of the safety and reversing devices and systems Important information for the user Once...

Page 16: ...sqm 18 0 sqm Rated lifting force 60 kgs 80 kgs 100 kgs 120 kgs Rail Steel Aluminum Steel Aluminum Steel Aluminum Steel Aluminum Drive Chain Belt Chain Belt Chain Belt Chain Belt Motor 24V 100W 24V 120W 24V 140W 24V 160W Input voltage 110V 270V 110V 270V 110V 270V 110V 270V LED 24V 14pcs LED bulbs Transformer 105 Temperature detect switch Radio frequency 433 92 MHz Coding format Rolling code 7 38x1...

Page 17: ...y Safety reverse function Obstruction or door maintenance required 1 Check for any obstructions 2 Call a Professional Technician for maintenance Transmitter doesn t work 1 Flat battery 2 Antenna is loose or not well extended 3 Signal interference 1 Replace battery 2 Extend the antenna on the opener 3 Eliminate signal interference doorbell baby monitor alarm etc Can t add new transmitters 1 Memory ...

Page 18: ...rees that they may be charged a call out fee plus any parts required to complete the repair Liability Australia only Under no circumstances shall the Seller be liable for consequential incidental or special damages arising in connection with the use or inability to use the Unit In no event shall the Seller s liability for damages or injury arising from breach of law or contract or for negligence e...

Page 19: ...______ _______ Contact Details ______________________________________________________________________________________________ Notes_________________________________________________________________________________________ ________________________________________________________________________________________________________ 2019 Jaytech ...

Reviews: