55
S
lideOut
S
yStemS
Trouble shooting the Inwall slideout system
Checking Fuses: The inwall slide requires a minimum 30 Amp fuse. Check the load
center for blown fuses and replace any if necessary. If the fuse blows immediately upon
replacement, there is a problem with the wiring to the inwall slide control box. A qualified
service person should be called to check and repair.
Obstructions:
Check outside the recreation vehicle for possible obstructions such as a tree, post or car etc.
Check inside the vehicle for any obstructions such as luggage, furniture or open cabinets etc.
Also check for smaller objects that may be wedged under the floor or in the sides of the unit.
Remove any obstructions before proceeding.
Error Codes:
Refer to error codes explained previously along with instructions on how to locate the inwall
slide controller.
Low Voltage:
The inwall slide controller is capable of operating the room with as little as 8 volts. But
at these lower voltages the amperage requirement is greater. Check the voltage at the
controller. If voltage is lower than 11 volts, it is recommended that the battery be placed on
a charger until it is fully charged. It may be possible to “jump” the RV battery temporarily
to extend or retract the room. Consult Customer Service before attempting to “jump” the
auxiliary battery.
Only 1 Side Moving:
The inwall room slide has a separate motor to operate each side of the room. Does only 1
side of the room move a short distance (2 to 4 inches) and stop? Will Non-moving side move
with help? If only 1 side of the room is moving, then with another person’s assistance press
the switch to extend or retract the room while pushing the non-moving side in the appropriate
direction. On larger rooms it may be necessary to have 2 or more people pushing the room.
Non-moving side moved manually:
Try to push the non-moving side in and out. If a motor shaft has broken then it will be
possible to move that side of the room several inches by hand. Larger rooms may require
several people to push.
Debris in the rack:
Check all 4 gear racks on the side of the room for debris.
Do the status LEDs light?
Locate the slide controller for the slideout in question. When the room slideout direction
switch is actuated, do the status LEDs light up. Check this in both the extend and retract
modes.
Manual override for the inwall slideout
The slideout system comes with an “electronic” manual override. In event the slide out
does not extend or retract follow these steps to override the system which should allow the
slideout to be retracted.
NOTE:
Fuses for the slideouts can be found in the load center and
may be designated as auxiliary or slideout motor..
Table of Contents
Maintenance Record
Summary of Contents for 2016 Melbourne
Page 1: ...2016 CAMPING TRAILERS PRINTED ON RECYCLED PAPER 2016 MELBOURNE CLASS C MOTORHOMES 0189568 2016...
Page 2: ......
Page 4: ......
Page 12: ...2...
Page 62: ...52 Vehicle Operation...
Page 90: ...80 Electrical System...
Page 130: ...120 Plumbing System Notes...
Page 142: ...132 Electronics Notes...
Page 150: ...140 Interior Notes...
Page 156: ...146 Exterior Notes...
Page 160: ...150 Travel Camping Storage Checklists Notes...
Page 164: ...154 Additional Information Notes...
Page 166: ...156 Additional Information Notes...
Page 167: ...157 Additional Information Notes Table of Contents Maintenance Record...
Page 168: ...158 Additional Information Notes...
Page 169: ...159 Additional Information Notes Table of Contents Maintenance Record...