The temperature and pressure relief valve is designed to open if the temperature of the water
within the heater reaches 120° F, or if the water pressure in the heater reaches 150 pounds.
When this pressure is reached, the pressure relief valve will open and water will drip from
the valve.
This “weeping” or dripping will continue until the pressure is reduced to below 150 pounds,
and the valve closes. This condition is normal and does not indicate a defective relief valve.
One way to reduce the frequency of this occurrence is to maintain an air pocket at the top
of the water heater tank. This air pocket will form in the tank by design; however, it will be
reduced over time by the everyday use of your water heater. To replenish this air pocket:
4. Turn off the water heater.
5. Turn off the cold water supply line.
6. Open a faucet in the motor home.
7. Pull out the handle of the pressure relief (P&T) valve and allow water to flow from the
valve until it stops.
8. Release the handle on the P&T valve - it should snap closed.
Close the faucet and turn on the cold water supply. As the tank fills, the air pocket will
develop. Repeat this procedure as often as needed to reduce the frequency of the weeping
P&T valve.
Maintenance
Do not allow the burner to burn with a yellow flame, or continue to operate the water heater
with an improper burner flame.
Periodically, inspect the water heater vent for soot. Soot is a sign of incomplete combustion
and must be corrected before operating the water heater. This is your visual warning that the
water heater is operating in an unsafe manner. If soot is present, immediately shut the unit
down and contact your dealer or a qualified service agency.
Periodically inspect the vent for obstructions. Do not terminate the vent on your water
heater inside of add-on rooms, screen porches or patios. Doing so will result in products of
combustion being vented into the rooms or occupied areas.
Draining and winterization:
If the recreation vehicle is to be stored over the winter months, the water heater must be
drained to prevent damage from freezing. Damage to the water heater caused by freezing
is not warrantable. It is recommended the water heater be
drained and bypassed during
the winterization process,
particularly if introducing RV antifreeze into the plumbing
system. The water heater should never be drained when HOT or UNDER PRESSURE.
To drain the water heater:
1. Turn off electrical power to the water heater either at the switch from the electrical
element of at the breaker.
2. Shut off the propane supply to the water heater.
3. Turn off the water pump.
4. Open both hot and cold water faucets.
5. Remove the anode rod from the tank.
For detailed information see the
Winterizing the Plumbing System and Water Heater Bypass
sections of this manual.
Table of Contents
Maintenance Record
Summary of Contents for 2016 Melbourne
Page 1: ...2016 CAMPING TRAILERS PRINTED ON RECYCLED PAPER 2016 MELBOURNE CLASS C MOTORHOMES 0189568 2016...
Page 2: ......
Page 4: ......
Page 12: ...2...
Page 62: ...52 Vehicle Operation...
Page 90: ...80 Electrical System...
Page 130: ...120 Plumbing System Notes...
Page 142: ...132 Electronics Notes...
Page 150: ...140 Interior Notes...
Page 156: ...146 Exterior Notes...
Page 160: ...150 Travel Camping Storage Checklists Notes...
Page 164: ...154 Additional Information Notes...
Page 166: ...156 Additional Information Notes...
Page 167: ...157 Additional Information Notes Table of Contents Maintenance Record...
Page 168: ...158 Additional Information Notes...
Page 169: ...159 Additional Information Notes Table of Contents Maintenance Record...