xlviii
Ground line
Alarm Input
1, 2, …, 16.. It becomes valid in low voltage.
1-NO C
,
2-NO C
,
3-NO C
Three NO activation outputs.
485 A/B
485 communication port. They are used to control devices such as
PTZ. Please parallel connect 120
Ω between A/B cables if there are
too many PTZ decoders.
You can refer to the following sheet and Figure 3-18 for alarm input and output information.
Figure 3-18
In the first line, from
the left to the right,:
1
,
2
,
3
,
4
,
5
,
6
,
7
,
8
,
9
,
10
,
11
,
12
,
13
,
14
,
15
,
16
ALARM 1 to ALARM 16. The alarm becomes active in low voltage.
In the second line,
from the left to the
right:
NO1 C1
,
NO2 C2
,
NO3 C3
,
NO4 C4,
NO5 C5 NC5
The first four are four groups of normal open activation output
(on/off button)
NO5 C5 NC5 is a group of NO/NC activation output (on/off button)
CTRL 12V
Control power output. You need to close the device power to cancel
the alarm.
+12V
It is external power input. Need the peripheral equipment to provide
+12V power (below 1A).
Earth cable.
485 A/B
485 communication port. They are used to control devices such as
PTZ. Please parallel connect 120T
Ω between A/B cables if there are
too many PTZ decoders.
3.7.2 Alarm Input Port
Please refer to the following sheet for more information. See Figure 3-19.
Normal open or Normal close type
Please parallel connect COM end and GND end of the alarm detector (Provide external
power to the alarm detector).
Please parallel connect the Ground of the DVR and the ground of the alarm detector.
Please connect the NC port of the alarm sensor to the DVR alarm input(ALARM)
AB connection port
Summary of Contents for N5 series
Page 1: ...i N5 Series Standalone DVR User s Manual...
Page 2: ...1...
Page 33: ...xxxi Figure 2 10 2 3 3 2U Series Please refer to Figure 2 11 for connection sample...
Page 70: ...lxviii Figure 4 24 Figure 4 25 Figure 4 26 Figure 4 27...
Page 110: ...cviii Figure 6 11...
Page 167: ...clxv Samsung HA101UJ CE 1T SATA...