background image

3

Table of Contents

GENERAL DESCRIPTION..............................................................................................4

PWR KEY AND STAT LED.............................................................................................4

FN KEY AND REC LED ..................................................................................................5

HOW TO CLEAR NVRAM...............................................................................................5

CHANGE SERIAL A SPEED TO 9600 ...........................................................................5

EXTENDED INFORMATION (EI) MODE ........................................................................5

INTERNAL MODEM OPERATION STATUS ..................................................................6

Summary of Contents for MINTER

Page 1: ...MINTER User s Manual Revision May 31 1999 ...

Page 2: ...including but not limited to the implied warranties or conditions of merchantability or fitness for a particular purpose For updated manuals and software or product release information you may visit JPS WWW site at http www javad com or contact JPS Customer Support by e mail support javad com Copyright 1998 Javad Positioning Systems All rights reserved ...

Page 3: ... Table of Contents GENERAL DESCRIPTION 4 PWR KEY AND STAT LED 4 FN KEY AND REC LED 5 HOW TO CLEAR NVRAM 5 CHANGE SERIAL A SPEED TO 9600 5 EXTENDED INFORMATION EI MODE 5 INTERNAL MODEM OPERATION STATUS 6 ...

Page 4: ...en and yellow MINTER has an ON OFF key PWR and a function key FN MINTER also has protection against stuck keys e g when a key is held down unintentionally for a long time by other objects in a backpack PWR Key and STAT LED To turn on the receiver push the PWR key and release it To turn it off press the PWR key for more than 1 and less then 4 seconds during this period the STAT LED remains off to a...

Page 5: ...stem During this operation the REC LED flashes yellow and the file system is not accessible for CDU applications or for data recording This operation may require from fractions of a second to several seconds depending on the reason it started and the amount of the internal memory How to Clear NVRAM It is possible to clear NVRAM using only MINTER To do that 1 Turn the receiver OFF 2 Press and hold ...

Page 6: ...s OK if it is yellow need to wait more if it is red some tests failed With good receiver antenna and observation conditions all blinks should be green in 10 minutes after power on Thresholds are 51 db Hz for SN ratio red if less for all locked satellites 3 ppm for frequency offset red if more 15 minutes for continuous tracking time Internal Modem Operation Status This information mode is available...