6
BOILER USAGE
OIL USAGE
The burner control thermostat is set in the proximity of 75
°
C or higher, thus producing more hot
Figure 3.
Oil side
1. Oil side cleansing hatch
2. Wood/oil side cleansing hatch
3. Burner hatch with flame observation
glass
4. Exit gas control (1 piece)
Maintenance
When the burner is correctly adjusted, the boiler needs sweeping approx. once a year. (see
adjustment values, page 4).
Before the oil chamber can be cleansed, power must be switched off from the burner’s main
switch. Then the oil burner hatch (nr. 3, figure 3.) and cleansing hatch (nr. 1, figure 3) are
opened and the exit gas control, found behind the latter hatch, is removed (nr. 4, figure 3).
The chambers are cleansed by removing and extracting the smut from the surfaces.
After cleansing the exit gas control is replaced, the hatches are closed and power is switched
back on.
If the boiler has not been equipped with an electric immersion heater upon delivery, it can also
be installed later (contact your dealer or manufacturer).
When heated with oil, the control thermostat of the electric heating resistance is set to 60
°
C.
on the fire surfaces and can damage the boiler.
domestic water. Too low temperature in the boiler (below 70
°
C) will produce condensation