TROUBLE SHOOTING GUIDE

If you believe the MicroSilk

®

 Demonstration system to be within the warranty period, you must contact 

Jason Customer Service: 1-800-255-5766

 with the bath’s Product and Serial numbers before work is started.

All warranty repairs must be authorized by Jason before work is started.

FOR SERVICE, ALWAYS CONTACT YOUR DEALER OR AUTHORIZED SERVICE CENTER

WARNING: Always turn off power at the main electrical service panel when servicing the bath.

MICROSILK PUMP SYSTEM

SYMPTOMS

POSSIBLE CAUSES

RECOMMENDED ACTION

MicroSilk

®

 system fails to 

operate.

a)     No power to the MicroSilk

®

 unit.

b)     Motor is not plugged in.

c)     Touch Control — insufficient water 

in bath.

a)     Reset circuit breakers and GFCI if tripped. Check fuses 

and replace if bad.

        Check voltage at motor when control is on. If no voltage, 

the control is defective. If voltage is present, motor is 

defective.

b)     Make sure plug is fully inserted into the outlet.

c)     Fill bath to recommended level (3” above jets).

Pump operates, but no Micro 

Bubbles are injected into water.

a)     Air Intake clogged.

a)     Refer to Jason Customer Service.

Pump operates, but water is 

not being pumped.

a)     Suction or discharge blocked.

b)     Suction air leak. 

(System usually 

surges.)

a)     Remove obstruction.

b)     Make sure connection is tight on suction side 

of the pump.

Pump does not manually shut 

off.

a)     Control defective.

a)     Refer to Jason Customer Service.

Pump shuts off by itself, or 

before set time elapses. 

a)     Pump motor overheated and thermal 

protection device deactivated motor. 

(possibly low voltage).

b)     GFCI tripped.

a)     Make sure motor air cooling vents are not blocked, clea 

and allow motor to cool down.

 (Check service & wire size.)

b)     Refer to Jason Customer Service.

Pump leaks at shaft.

a)    Damaged or defective shaft seal.

a)     Refer to Jason Customer Service.

LED Light will not operate

a)    Light bulb is  loose in the socket.

a)    Access light bulb and assure that it is properly installed in 

the socket.

WHIRLPOOL BATH

SYMPTOMS

POSSIBLE CAUSES

RECOMMENDED ACTION

Whirlpool system fails to 

operate.

a)     No power to the Whirlpool unit.

b)     Not wired correctly

c)     Air switch - plastic air tube disconnected 

or broken

a)     Reset circuit breakers and GFCI if tripped. Check fuses 

and replace if bad.

b)     Make sure power supply is correctly wired in the unit

c)     Check, reconnect or replace tubing as necessary

Pump operates, but no air 

are injected into water.

a)     Air Intake clogged.

a)     Contact installer/dealer.

Pump operates, but water 

is not being pumped.

a)     Suction or discharge blocked.

b)     Suction air leak (System usually surges)

c)     Insufficient water level

a)     Remove obstruction.

b)     Make sure connection is tight on suction side of the pump.

c)     Fill bath to recommended level. Must be 2” above jets.

Pump runs but jets will not 

operate.

a)    Jets are completely or partially closed

a)     Adjust jets by rotating outer flange.

Pump does not manually 

shut off.

a)     Air switch tube disconnected or broken

a)     Reconnect or replace plastic air tube

Pump unions leak 

a)     Unions undertightened, overtightened, 

cracked or O-ring is not seated properly

a)     Back off union nut, check and straighten O-ring, replace 

as necessary, retighten.  

HAND TIGHTEN ONLY!

Pump shuts off by itself.

a)     Insufficient water

a)     Make sure bath is filled at least 2” above the highest jets.

Pump leaks at shaft.

a)    Damaged or defective shaft seal.

a)     Refer to Jason Customer Service.

Optional LED Light will not 
operate

a)    Light bulb is  loose in the socket.

a)    Access light bulb and assure that it is properly installed.

Summary of Contents for Vivere Series

Page 1: ...inspect the unit Failure of the carrier to respond should be reported to the seller and carrier Always file a freight claim promptly If the carton shows any sign of damage thoroughlyinspecttheproduct...

Page 2: ...rictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physicia...

Page 3: ...nts des antihistaminiques vasoconstricteurs vasodilatateurs les hypnotiques les narcotiques ou des tranquillisants F Personnesayantdesant c dentsdemaladiecardiaque d hypotensionoud hypertensionart rie...

Page 4: ...cal and plumbing connections should be made by a qualified professional NOTE Failure to follow these pre installation proce dures could result in voiding the warranty The manu facturer will not be lia...

Page 5: ...se the electrical service from the GFCI to the bath control should be direct and not interrupted by a switch Never use a switch in conjunction with a control device This will VOID THE MANUFACTURER S W...

Page 6: ...nt Off and then drain the water The bath unit and its plumbing are designed to drain after each use whether used as a hydrotherapy bath or soaking bath EXTENSION PANEL INSTALLATION The Vivere Collecti...

Page 7: ...er designed to eliminate the potential of hair and body entrapment MICROSILK OPERATION All Jason MicroSilk baths are pre plumbed at the factory with standard equipment Standard equipment includes a Mi...

Page 8: ...per access to bath equipment 4 Make sure that all the plumbing and fixtures in the bathroom are in good working order and have no leaks 5 Do not use carpeting or other materials or furniture which can...

Page 9: ...ing vents are not blocked clea and allow motor to cool down Check service wire size b Refer to Jason Customer Service Pump leaks at shaft a Damaged or defective shaft seal a Refer to Jason Customer Se...

Reviews: