JASON Hydrotherapy AC635PS Owner'S Manual Download Page 8

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 8 of 15

 

 

 

 

Customer Service :  800.255.5766 

Copyright © 2010 Jason International.

CLEANING

1.  Remove all loose debris

 both inside the bathwell and around 

the blower. Construction plaster or excess grout can be 
removed with the use of a wood (edge) trowel. 

2, 

Paint or tar stains

 can be removed with a cleaner such as 

paint  thinner,  turpentine,  or  isopropyl  alcohol  (rubbing 
alcohol).  Never  allow  the  cleaner  to  soak  against  the 
acrylic surface for long periods of time. 

Always rinse the 

surface immediately

 following the use of cleaners. 

Note:

  Follow  the  manufacturers  instructions  for  safely 

using these or similar products. If the surface becomes 
scratched or dulled, it may be restored by using a quality 
plastic polish, i.e., Novus Plastic Polish No. 2. 

It is always 

preferable to protect the acrylic surface during installation to 

minimize cleanup and prevent surface damage.

INSTALLATION INSTRUCTIONS (cont.)

wATER TESTING

Before finishing the installation, it is recommended that the 
bath be water tested and the plumbing tested for leaks.

1. 

Before water testing the bath

, make sure that all plumbing 

connections are tight.  DO NOT OVERTIGHTEN.

2. 

Fill and operate the bath.  

Close the drain and fill the bath with 

water to at least 10 inches [25 cm] below the bath deck. The 
inlet temperature should not exceed 104°F (40°C) as this 
could damage the acrylic surface.

3, 

Inspect the plumbing for leaks

.

4. 

Turn the blower Off and then drain the water.

    The  bath  unit 

and  its  plumbing  are  designed  to  drain  after  each  use 
whether used as an air bath, soaking bath, or when taking 
a shower.

Summary of Contents for AC635PS

Page 1: ...y and is the responsibility of the installer ALL WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE MUST BE MADE PRIOR TO INSTALLATION To protect the unit from damage keep the bath in its carton until ready for installation EQUIPMENT ACCESS In accordance with Building Codes service access to all therapy bath equipment controls and electrical connections must be provided during installation Insufficient acc...

Page 2: ...nd four 4 water inlet stub out positions have been indicated on the template Choose the water inlet stub out position that is preferable for your installation 9 Remove the template and cut out the floor CAUTION The floor drain location must be installed according to the template This location is critical to the proper installation of this product Note You must keep the template it will be needed d...

Page 3: ...ount a deck mounted diverter valve on the deck of the bath If a hand held shower is desired consider a floor mounted faucet or a faucet with an above deck diverter If a floor mounted faucet is desired be sure to install the faucet to allow for sufficient overhang into the well of the bath This will ensure an unobstructed water flow out of the faucet when filling the bath Follow the faucet manufact...

Page 4: ...n factory installed following E T L guidelines During installation if remote mounting of the blower and its control box is desired follow these procedures Note Do not remote mount the blower and control box more than 15 feet 457 cm away from the air inlet of the bath Choose a location as close as possible to the bath to assure maximum efficiency 1 Determine layout The installer is to determine the...

Page 5: ...not use a sand bed to install or level the bath Note The bottom of the bath s Level Form Base must be 1 8 lower than the bottom of the skirt 11 Drain and overflow Complete the installation of the drain and overflow per the instructions included with the drain and overflow 12 Test bath controls Before finishing the installation it is recommendedthatthebathcontrolsbetestedwithoutfilling the bath wit...

Page 6: ...trol Box Standard Edition AirMasseur The blower is prewired to its control box The control box has a 36 inch 91 cm cord with a plug end The AirMasseur control box is mounted on a stand This stand is temporarily secured to the packing board for shipping During installation the control box and mount must be positioned horizontally and located to permit access for inspection and servicing The AirMass...

Page 7: ...temperature sensor must be plugged into the proper receptacles for correct operation of the AirMasseur system See Figure 12 for connections A The junction box for the blower control box must be connected into a 240v 15 amp GFCI dedicated circuit B Pre wired power cord to blower C and ozone unit G Six pin mini DIN terminals for the water temperature sensor D and LED light E to the control box Eight...

Page 8: ... may be restored by using a quality plastic polish i e Novus Plastic Polish No 2 It is always preferable to protect the acrylic surface during installation to minimize cleanup and prevent surface damage INSTALLATION INSTRUCTIONS cont WATER TESTING Before finishing the installation it is recommended that the bath be water tested and the plumbing tested for leaks 1 Before water testing the bath make...

Page 9: ...TIC PURGE Twenty 20 minutes after the control has shut off and the bath is completely drained the blower will start again for a 2 minute purge cycle that dries the air channel Note that the LCD display will read PURGE and begin to countdown the 10 or 20 minute pause before the purge cycle begins The readout will display PURGE ON during the purge cycle Any time during the pause before the purge cyc...

Page 10: ...g the plumbing lines clean and fresh The ozone system works automatically in conjunction with the blower motor Touchpad A main control touchpad mounted on the bath deck features an LCD readout which alternately indicates the water temperature 5 F 15 C and air bath time remaining The touchpad operates all functions of the blower as well as the LED Mood light Refer to the Signature Edition AirMasseu...

Page 11: ... icon a third time moves the blower back to Constant mode Blower Speeds Icon The Blower Speeds icon is used to increase or decrease the blower speed once the blower is On Press and hold the icon to decrease the blower speed until the desired intensity is reached then release Pressandholdtheiconagaintoincreasetheblowerspeed until the desired intensity is reached The blower will return to its highes...

Page 12: ...Light Cycle is displayed if pressed for more than two 2 seconds Customized Settings The12characterLCDdisplaycanbecustomizedbypressing the Blower and Blower Speeds icons simultaneously for five 5 seconds while the system is Off Note The Blower Speeds icon will not be illuminated during this process Use the above figure to locate the icon A menu see below will bedisplayedtochoosethefollowing Purge24...

Page 13: ...VE liquid detergent solution i e glass cleaner and a soft wet cloth or sponge Do not run the air system with foaming cleaners or soaps Rinse the bath thoroughly after cleaning SURFACE MAINTENANCE Areas with minor scratches or dull surfaces can be restored by applying commercially available plastic polish i e Novus Plastic Polish No 2 available at your Jason dealer followed by an application of acr...

Page 14: ...nto the outlet c Keypad is disconnected c Check and reconnect if necessary Blower shuts off by itself or before time elapses a Blower motor overheated and thermal protection device deactivated motor possibly low voltage a Check that blower has sufficient ventilation and that the intake into the blower is not blocked Clear and allow the motor to cool down Check service wire size b GFCI tripped b Re...

Page 15: ...h the possibility of drowning Never use the therapy bath while under the influence of alcohol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a therapy bath G Persons using medication...

Reviews: