background image

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 12 of 15

 

 

 

 

Customer Service :  800.255.5766 

Copyright © 2010 Jason International.

SIGNATURE EDITION AIRMASSEUR

®

 TOUCHPAD

blower On/Off, Modes Icon

To control the operation of the Blower, simply press and hold 
the icon to change the setting to Constant, Wave, Pulse or 
Off. A 20 minute decreasing timer will be initiated when the 
blower motor starts. Press and release the Blower icon once 
to display the current blower mode and speed. The Blower 
icon should remain lit as long as the bath is connected to a 
power supply. The LCD will display “Const Air” and blower 
speed,  “Wave  Air”  and  blower  speed,  or  “Pulse  Air”  and 
blower speed, while the icon is pressed. The time remaining 
on the purge cycle is displayed after the bath has drained. 
“Purge Stop” is displayed while the Blower On/Off icon is 
pressed during the purge cycle. This action will terminate 
the purge cycle. The mode settings will be remembered on 
the next startup.

blower Speeds Icon

Hold the icon in Constant mode to go from High to Low then 
release and hold again to go from Low to High. Hold the icon 
in Wave and Pulse mode to go from High to Medium and 
Medium to High. The system remembers the last speed setting 
on the next startup. The icon will light up when the blower is 
running. The LED displays the blower speed from “10” (Low) 
or “55” (Med) to “99” (High) while the icon is pressed. You 
can reduce the auto purge idle time from 20 minutes to 10 
minutes by pressing and holding the Blower Speeds icon for 
more than 5-seconds during the purge idle period.

Light (Light Icon)

Hold the icon for less than 2 seconds to turn the lights off 
or  on.  Hold  the  icon  for  more  than  2  seconds  to  change 
modes. The Light icon should remain lit as long as the bath 
is connected to a power supply. This function has a teo (2) 
hour timer and remembers the last mode. The LCD displays 
“Light On” or “Light Off” while the icon is pressed for less 
than two (2) seconds. “Light Cycle” is displayed if pressed 
for more than two (2) seconds. 

Customized Settings

The 12 character LCD display can be customized by pressing 
the  Blower  and  Blower  Speeds  icons  simultaneously  for 
five (5) seconds, while the system is Off. 

Note:

 The Blower 

Speeds icon will not be illuminated during this process. Use 
the above figure to locate the icon. A menu (see below) will 
be displayed to choose the following: Purge 24, (starts blower 
every 24 hours for two (2) minutes at the time the purge was 
set); Product Test Diagnostics; Temperature (F or C); and 
Language (English or Spanish).

Menu Instructions

Use  the  Blower  icon  to  scroll  through  the  different  menu 
items.  Use  the  Blower  Speeds  icon  to  change  an  option. 
For example, press and release the Blower icon to change 
from Purge 24 to Product Test; press and release again to 
arrive at the Temperature option. Then press and release 
the Blower Speeds icon to change the temperature display 
from F (Fahrenheit) to C (Celsius).

Product Test Diagnostics

After selecting the Product Test option from the menu, the unit 
will perform a series of tests to confirm correct installation of 
components. The test will begin by displaying the configuration 
number,  followed  by  the  software  revision  number.  Next, 
the display will test the Temperature and Low Water Level 
sensor (ITW-209). Next, each of the six (6) icon buttons will 
begin to light. Press the illuminated button to proceed to the 
next icon. After the icon test, the blower will start for two (2) 
seconds on the high setting. Lastly, the LED Light unit will 
be tested. If you receive an error on any of the tests, confirm 
proper installation of the component to the correct control 
box. (See Figure 12 on page 7.)

Remote Control

The Signature Edition control system includes a waterproof 
floating Universal Remote Control. It controls all bath func-
tions plus a TV, DVD, CD, etc. which can be heard through 
the optional Sound Immersion System.

Figure 14

Blower On/Off, Modes

Blower Speeds

LED Light

IR for Remote

OPERATING INSTRUCTIONS, fEATURES, AND CONTROLS (cont.)

Use the various touchpad icons to access all of functions of 
the control box used in a Jason Signature Edition AirMasseur

®

 

bath. 

Summary of Contents for AC635PS

Page 1: ...y and is the responsibility of the installer ALL WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE MUST BE MADE PRIOR TO INSTALLATION To protect the unit from damage keep the bath in its carton until ready for installation EQUIPMENT ACCESS In accordance with Building Codes service access to all therapy bath equipment controls and electrical connections must be provided during installation Insufficient acc...

Page 2: ...nd four 4 water inlet stub out positions have been indicated on the template Choose the water inlet stub out position that is preferable for your installation 9 Remove the template and cut out the floor CAUTION The floor drain location must be installed according to the template This location is critical to the proper installation of this product Note You must keep the template it will be needed d...

Page 3: ...ount a deck mounted diverter valve on the deck of the bath If a hand held shower is desired consider a floor mounted faucet or a faucet with an above deck diverter If a floor mounted faucet is desired be sure to install the faucet to allow for sufficient overhang into the well of the bath This will ensure an unobstructed water flow out of the faucet when filling the bath Follow the faucet manufact...

Page 4: ...n factory installed following E T L guidelines During installation if remote mounting of the blower and its control box is desired follow these procedures Note Do not remote mount the blower and control box more than 15 feet 457 cm away from the air inlet of the bath Choose a location as close as possible to the bath to assure maximum efficiency 1 Determine layout The installer is to determine the...

Page 5: ...not use a sand bed to install or level the bath Note The bottom of the bath s Level Form Base must be 1 8 lower than the bottom of the skirt 11 Drain and overflow Complete the installation of the drain and overflow per the instructions included with the drain and overflow 12 Test bath controls Before finishing the installation it is recommendedthatthebathcontrolsbetestedwithoutfilling the bath wit...

Page 6: ...trol Box Standard Edition AirMasseur The blower is prewired to its control box The control box has a 36 inch 91 cm cord with a plug end The AirMasseur control box is mounted on a stand This stand is temporarily secured to the packing board for shipping During installation the control box and mount must be positioned horizontally and located to permit access for inspection and servicing The AirMass...

Page 7: ...temperature sensor must be plugged into the proper receptacles for correct operation of the AirMasseur system See Figure 12 for connections A The junction box for the blower control box must be connected into a 240v 15 amp GFCI dedicated circuit B Pre wired power cord to blower C and ozone unit G Six pin mini DIN terminals for the water temperature sensor D and LED light E to the control box Eight...

Page 8: ... may be restored by using a quality plastic polish i e Novus Plastic Polish No 2 It is always preferable to protect the acrylic surface during installation to minimize cleanup and prevent surface damage INSTALLATION INSTRUCTIONS cont WATER TESTING Before finishing the installation it is recommended that the bath be water tested and the plumbing tested for leaks 1 Before water testing the bath make...

Page 9: ...TIC PURGE Twenty 20 minutes after the control has shut off and the bath is completely drained the blower will start again for a 2 minute purge cycle that dries the air channel Note that the LCD display will read PURGE and begin to countdown the 10 or 20 minute pause before the purge cycle begins The readout will display PURGE ON during the purge cycle Any time during the pause before the purge cyc...

Page 10: ...g the plumbing lines clean and fresh The ozone system works automatically in conjunction with the blower motor Touchpad A main control touchpad mounted on the bath deck features an LCD readout which alternately indicates the water temperature 5 F 15 C and air bath time remaining The touchpad operates all functions of the blower as well as the LED Mood light Refer to the Signature Edition AirMasseu...

Page 11: ... icon a third time moves the blower back to Constant mode Blower Speeds Icon The Blower Speeds icon is used to increase or decrease the blower speed once the blower is On Press and hold the icon to decrease the blower speed until the desired intensity is reached then release Pressandholdtheiconagaintoincreasetheblowerspeed until the desired intensity is reached The blower will return to its highes...

Page 12: ...Light Cycle is displayed if pressed for more than two 2 seconds Customized Settings The12characterLCDdisplaycanbecustomizedbypressing the Blower and Blower Speeds icons simultaneously for five 5 seconds while the system is Off Note The Blower Speeds icon will not be illuminated during this process Use the above figure to locate the icon A menu see below will bedisplayedtochoosethefollowing Purge24...

Page 13: ...VE liquid detergent solution i e glass cleaner and a soft wet cloth or sponge Do not run the air system with foaming cleaners or soaps Rinse the bath thoroughly after cleaning SURFACE MAINTENANCE Areas with minor scratches or dull surfaces can be restored by applying commercially available plastic polish i e Novus Plastic Polish No 2 available at your Jason dealer followed by an application of acr...

Page 14: ...nto the outlet c Keypad is disconnected c Check and reconnect if necessary Blower shuts off by itself or before time elapses a Blower motor overheated and thermal protection device deactivated motor possibly low voltage a Check that blower has sufficient ventilation and that the intake into the blower is not blocked Clear and allow the motor to cool down Check service wire size b GFCI tripped b Re...

Page 15: ...h the possibility of drowning Never use the therapy bath while under the influence of alcohol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a therapy bath G Persons using medication...

Reviews: