IMPORTANT SAFETY INSTRUCTIONS

INSTRUCTIONS PERTAINING TO THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO 

PERSONS.

This manual contains information and instructions for proper operation and maintenance of your therapy bath.  Failure to 
follow these instructions could result in personal injury, electrical shock, or fire.

WARNING:  When  using  this  unit,  basic  precautions  should  always  be  followed,  including  the 

following:

READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY

DANGER:

 

TO REDUCE THE RISK OF INJURY FOLLOW THESE PRECAUTIONS: 

A.

  Do not permit children to use this product unless they are closely supervised at all times.

B.

  Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by the 

manufacturer.

C.

  The water in a  therapy bath should never exceed 104°F (40°C). Water temperatures between 100°F (38°C) and 104°F 

(40°C) are considered safe for a healthy adult. Use time should be limited to approximately 30 minutes, followed by 
a shower to cool down. Longer exposures may result in hyperthermia. The symptoms of this condition are nausea, 
dizziness and fainting, and it can be fatal. Lower water temperatures are recommended for extended use (exceeding 
10 -15 minutes) and for young children.

D.

  Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy, 

pregnant or possibly pregnant women should limit therapy bath water temperatures to 100°F (38°C).

E.

  The  use  of  drugs  or  alcoholic  beverages  before  or  during  therapy  bath  use  may  lead  to  unconsciousness  with  the 

possibility of drowning. Never use the therapy bath while under the influence of alcohol, anticoagulants, stimulants,  
antihistamines, vasoconstrictors, vasodilators, hypnotics, narcotics, or tranquilizers.

F.

  Persons with a medical history of heart disease, low or high blood pressure, circulatory system problems, or diabetes 

should consult a physician before using a therapy bath.

G.

  Persons using medication should consult a physician before using a therapy bath since some medication may induce 

drowsiness while other medication may affect heart rate, blood pressure, and circulation.

DANGER:

 

 

To reduce the risk of injury, enter and exit the bath slowly. 

WARNING:

 Never operate electrically connected devices in or near the bath. Never drop or insert any object into any opening.

This unit must be connected to a supply circuit that is protected by a GFCI. Such a device should be installed by a licensed 
electrician and should be tested on a regular basis (at least monthly). To test the GFCI push the 

TEST

 button. The GFCI 

should interrupt the power. Push the 

RESET

 button and the power should be restored. If the GFCI fails to operate in this 

manner, there is the possibility of an electric shock. 

DO NOT USE. 

Disconnect the unit and have the problem corrected by a 

qualified service technician. 
To avoid the possibility of personal injury and discoloration of the acrylic surface, the inlet water temperature should not 
exceed 104°F (40°C). The bath should be drained after each use. Each bather should start their bath with fresh water. Do 
not use oil base additives in your therapy bath.

CAUTION: Do not use harsh abrasives or solvents for cleaning this unit.

INSTALLER/OWNER BEARS ALL RESPONSIBILITY TO COMPLY WITH ALL STATE  

AND LOCAL CODES WHEN INSTALLING THIS PRODUCT.

SAVE THESE INSTRUCTIONS

 

Jason InternatIonal, Inc.

8328 MacArthur Drive  •  North Little Rock  •  Arkansas  •  72118

www.jasoninternational.com 

Summary of Contents for AC635PS

Page 1: ...y and is the responsibility of the installer ALL WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE MUST BE MADE PRIOR TO INSTALLATION To protect the unit from damage keep the bath in its carton until ready for installation EQUIPMENT ACCESS In accordance with Building Codes service access to all therapy bath equipment controls and electrical connections must be provided during installation Insufficient acc...

Page 2: ...nd four 4 water inlet stub out positions have been indicated on the template Choose the water inlet stub out position that is preferable for your installation 9 Remove the template and cut out the floor CAUTION The floor drain location must be installed according to the template This location is critical to the proper installation of this product Note You must keep the template it will be needed d...

Page 3: ...ount a deck mounted diverter valve on the deck of the bath If a hand held shower is desired consider a floor mounted faucet or a faucet with an above deck diverter If a floor mounted faucet is desired be sure to install the faucet to allow for sufficient overhang into the well of the bath This will ensure an unobstructed water flow out of the faucet when filling the bath Follow the faucet manufact...

Page 4: ...n factory installed following E T L guidelines During installation if remote mounting of the blower and its control box is desired follow these procedures Note Do not remote mount the blower and control box more than 15 feet 457 cm away from the air inlet of the bath Choose a location as close as possible to the bath to assure maximum efficiency 1 Determine layout The installer is to determine the...

Page 5: ...not use a sand bed to install or level the bath Note The bottom of the bath s Level Form Base must be 1 8 lower than the bottom of the skirt 11 Drain and overflow Complete the installation of the drain and overflow per the instructions included with the drain and overflow 12 Test bath controls Before finishing the installation it is recommendedthatthebathcontrolsbetestedwithoutfilling the bath wit...

Page 6: ...trol Box Standard Edition AirMasseur The blower is prewired to its control box The control box has a 36 inch 91 cm cord with a plug end The AirMasseur control box is mounted on a stand This stand is temporarily secured to the packing board for shipping During installation the control box and mount must be positioned horizontally and located to permit access for inspection and servicing The AirMass...

Page 7: ...temperature sensor must be plugged into the proper receptacles for correct operation of the AirMasseur system See Figure 12 for connections A The junction box for the blower control box must be connected into a 240v 15 amp GFCI dedicated circuit B Pre wired power cord to blower C and ozone unit G Six pin mini DIN terminals for the water temperature sensor D and LED light E to the control box Eight...

Page 8: ... may be restored by using a quality plastic polish i e Novus Plastic Polish No 2 It is always preferable to protect the acrylic surface during installation to minimize cleanup and prevent surface damage INSTALLATION INSTRUCTIONS cont WATER TESTING Before finishing the installation it is recommended that the bath be water tested and the plumbing tested for leaks 1 Before water testing the bath make...

Page 9: ...TIC PURGE Twenty 20 minutes after the control has shut off and the bath is completely drained the blower will start again for a 2 minute purge cycle that dries the air channel Note that the LCD display will read PURGE and begin to countdown the 10 or 20 minute pause before the purge cycle begins The readout will display PURGE ON during the purge cycle Any time during the pause before the purge cyc...

Page 10: ...g the plumbing lines clean and fresh The ozone system works automatically in conjunction with the blower motor Touchpad A main control touchpad mounted on the bath deck features an LCD readout which alternately indicates the water temperature 5 F 15 C and air bath time remaining The touchpad operates all functions of the blower as well as the LED Mood light Refer to the Signature Edition AirMasseu...

Page 11: ... icon a third time moves the blower back to Constant mode Blower Speeds Icon The Blower Speeds icon is used to increase or decrease the blower speed once the blower is On Press and hold the icon to decrease the blower speed until the desired intensity is reached then release Pressandholdtheiconagaintoincreasetheblowerspeed until the desired intensity is reached The blower will return to its highes...

Page 12: ...Light Cycle is displayed if pressed for more than two 2 seconds Customized Settings The12characterLCDdisplaycanbecustomizedbypressing the Blower and Blower Speeds icons simultaneously for five 5 seconds while the system is Off Note The Blower Speeds icon will not be illuminated during this process Use the above figure to locate the icon A menu see below will bedisplayedtochoosethefollowing Purge24...

Page 13: ...VE liquid detergent solution i e glass cleaner and a soft wet cloth or sponge Do not run the air system with foaming cleaners or soaps Rinse the bath thoroughly after cleaning SURFACE MAINTENANCE Areas with minor scratches or dull surfaces can be restored by applying commercially available plastic polish i e Novus Plastic Polish No 2 available at your Jason dealer followed by an application of acr...

Page 14: ...nto the outlet c Keypad is disconnected c Check and reconnect if necessary Blower shuts off by itself or before time elapses a Blower motor overheated and thermal protection device deactivated motor possibly low voltage a Check that blower has sufficient ventilation and that the intake into the blower is not blocked Clear and allow the motor to cool down Check service wire size b GFCI tripped b Re...

Page 15: ...h the possibility of drowning Never use the therapy bath while under the influence of alcohol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a therapy bath G Persons using medication...