8. TROUBLESHOOTING

 

 

WARNING 

 

The following operation requires sufficient professional knowledge on electric aspect and 
comprehensive  safety  knowledge.  Operators  should  be  holders  of  valid  qualification 
certificates which can prove their skills and knowledge. 

 

Make sure the input cable of the machine is cut off from the electricity utility before 
uncovering the welding machine. 

 

The phenomena listed blow may be caused by the accessory and gas you use, the working 
environment or the power supply condition. Try to improve the working environment to avoid 
such occurrences. 

 

Table 8.1    General troubleshooting 

Phenomena 

Cause 

Solution 

There is no display on the 
control  panel  after  the 
machine is turned on. 

The  power  supply  is  not  well 
connected. 

Reconnect it. 

Machine failure 

Ask professionals for help. 

The fan does not work or 

works abnormally. 

The  3-phase  power  cord  is  not 
well connected. 

Reconnect  the  3-phase  power 
cord. 

Phase failure 

Solve the phase failure problem. 

The mains voltage is overly low.  Welding can be carried out after 

the mains voltage recovers. 

There is no no-load voltage 

output, the protection LED 

is on, and the meter 

displays “Err 003”. 

Air cooling/Water cooling switch 
is  switched  to  the  wrong 
position. 

Switch  the  air  cooling/water 
cooling  switch  to  the  correct 
position. 

The water circuit fails. 

Eliminate  the  water  circuit 
failure problem. 

There is no no-load voltage 
output, the protection LED 
is  on,  and  the  meter 
displays “Err 002”. 

Overheating protection 

It can recover automatically 

after the machine is cooled. 

There is no no-load voltage 
output, the protection LED 
is  on,  and  the  meter 
displays “Err 001”. 

The mains voltage is overly low.  Welding can be carried out after 

the mains voltage recovers. 

The mains voltage is overly high.  Disconnect the power supply with 

the  machine,  and  reconnect  it 
after 

the 

mains 

voltage 

recovers. 

Auxiliary power fails. 

Replace the fault circuit board 
of the auxiliary power. 

There is no no-load voltage 
output, the protection LED 
is  on,  and  the  meter 
displays “Err 000”. 

Overcurrent or damage of power 
parts 

Restart the machine. If 

overcurrent problem still 

exists, contact the service 

center of our company. 

 

Summary of Contents for MIG 350P

Page 1: ...MODEL MIG 350P N316 MIG 400P N317 INVERTER WELDER OPERATOR S MANUAL L2040A SC A4 You Can buy this product at our E shop i prek galite sigyti m s el parduotuv je BUY NOW www e serpantinas com...

Page 2: ......

Page 3: ...pply monitoring panel 10 5 2 Details of the functional zones on the power supply monitoring panel 11 6 OPERATION OF CONTROL PANELS 15 6 1 General operation steps for the control panel on the power sup...

Page 4: ...chnologies of this product are patented Operate after reading this manual carefully 1 JASIC has the right to modify this manual at any time without prior notice 2 Though contents in this manual have b...

Page 5: ...orking position is safe Smoke gas may be harmful to health Keep your head away from smoke and gas to avoid inhalation of exhaust gas from welding Keep the working environment well ventilated with exha...

Page 6: ...bundant functions This product has many welding modes available such as MIG MAG pulse MIG MAG and double pulse MIG MAG etc At the same time there are many optional operation modes under each welding m...

Page 7: ...signing this product so as to meet the personalized requirements of users to the largest extent For example this product provides a variety of welding torch operating modes and user defined modes Besi...

Page 8: ...pe Maximum diameter of wire spool S200 S300 300mm S200 S300 300mm Wire diameter 0 8 1 6mm 0 8 1 6mm 3 3 Functional parameters MMA MIG350P N316 MIG400P N317 Welding current range 10 350A 10 400A Arc fo...

Page 9: ...MAG PULSE SERIES 7 3 4 External characteristic This machine is with constant voltage external characteristic in pulsed welding and MIG MAG welding while it is with constant current external character...

Page 10: ...onitoring panel 2 Front panel 3 Parameter adjustment knob 4 Power output terminal 5 Power output terminal 6 Interface for the control cable 7 Back panel 8 Air switch 9 Fuse 10 Socket for CO2 heater ap...

Page 11: ...Description Power source of the heater Input cable of the welding machine Breaker ON Breaker OFF Table 4 3 Symbols on the nameplate Symbol Description Symbol Description U0 Rated no load voltage Gas...

Page 12: ...Current column parameters selecting zone 3 Current column parameters display window 4 Abnormity indicator 5 Voltage column parameters display window 6 Voltage column parameters selecting zone 7 Weldi...

Page 13: ...e selecting key and the corresponding LED will be on when a certain kind of base metal is selected Note There is no such function in MMA Figure 5 4 Gas selecting zone It contains components such as ga...

Page 14: ...uch as time and pitch ratio peak parameters such as time current speed thickness arc characteristic voltage proportion and frequency base parameters such as current speed and voltage downslope paramet...

Page 15: ...The voltage column parameters include 4 parameters namely voltage V time s proportion and frequency Hz Voltage column parameters display meter can display system information actual welding voltage an...

Page 16: ...nnels are indicated with channel numbers Working channel means the channel being used currently 1 To access the channel management mode Press the channel key in standby mode the channel LED will be on...

Page 17: ...ing zone Figure 5 5 if necessary 5 Select the operation mode Select the desired operation mode by pressing the selecting key in the operation mode selecting zone Figure 5 9 if necessary 6 Select the p...

Page 18: ...TIG welding is a kind of DC TIG welding achieved by users in MMA welding through adding necessary gas path equipment connected to the welding machine and igniting arc by scraping the electrode Various...

Page 19: ...nitial voltage It is located at initial segment voltage column voltage V and it varies with the change of the initial current or initial speed Beside this parameter can be adjusted within a certain ra...

Page 20: ...lsed MIG MAG welding namely pre flow time initial current initial speed initial voltage upslope time peak current peak speed peak voltage thickness of base metal arc characteristic spot welding time d...

Page 21: ...he desired welding mode base metal type gas type welding wire type and operation mode before any operation on parameters For most of the parameters in double pulse MIG MAG see the contents of 6 3 sect...

Page 22: ...alue then gradually rises or drops to the preset value Release the torch trigger current drops gradually and arc stops 4T mode Push the torch trigger arc is ignited and current rises to the initial va...

Page 23: ...rrosive gas or materials in the ambient air should not exceed the standard content except for such materials produced in the process of welding 9 Never use this welding source for pipe thawing 10 Do n...

Page 24: ...ble connecting the workpiece the resistance would be greater and the welding current would be unstable Besides overheating would lead to fire hazard Therefore please connect the base metal reliably wi...

Page 25: ...istance between the power input and the enclosure and make sure such insulation resistance should be greater than 10 ohms 5 Put the machine into the original packing in dry location if it is not used...

Page 26: ...ilure problem The mains voltage is overly low Welding can be carried out after the mains voltage recovers There is no no load voltage output the protection LED is on and the meter displays Err 003 Air...

Page 27: ...roperly Table 8 3 Troubleshooting in MIG MAG Phenomena Cause Solution The wire feeder loses communication with the welding power supply The control cable is disconnected Connect the control cable The...

Page 28: ...egulator cannot be heated The plug of the heater is well connected Connect it well The heater wire is shorted Repair the heater wire The resettable fuse inside the machine functions Shut down the mach...

Page 29: ...OPERATOR S MANUAL MIG MAG PULSE SERIES 27 APPENDIX...

Page 30: ...OPERATOR S MANUAL MIG MAG PULSE SERIES 28...

Reviews: