background image

  OPERATOR’S MANUAL

 ·

 MIG/MAG PULSE SERIES                                                                                                                                                                                                                                                           

- 18 -   

     

is especially important when welding under low current. Users may adjust it according to their own 
technical requirements or operation habits. 
Spot welding time 
It is located at “peak segment-voltage column-time (s)”, and it makes sense only in spot welding. 

11)  Downslope time 

It is located at “downslope segment-voltage column-time (s)”. The craters can be filled by adjusting 
this parameter properly in non programmed 4T mode. 

12)  Crater current 

It is located at “crater segment-current column-current (A)”, and it varies with the change of the 
crater speed. Therefore, it is unnecessary to set this parameter when the crater speed is set properly. 

13)  Crater speed 

It is located at “crater segment-current column-wire feed speed (m/min)”, and it varies with the 
change of the crater current. Therefore, it is unnecessary to set this parameter when the crater current 
is set properly. 

14)  Crater voltage 

It is located at “crater segment-voltage column-voltage (V)”, and it varies with the change of the 
crater current or crater speed. Beside, this parameter can be adjusted independently within a certain 
range. 

15)  Post-flow time 

It is located at “postposed segment-voltage column-time (s)”, and users can set it according to their 
own technical requirements. 

 
 
6.4 Parameters in pulsed MIG/MAG 

There are 16 adjustable parameters in pulsed MIG/MAG welding, namely pre-flow time, initial current, 
initial speed, initial voltage, upslope time, peak current, peak speed, peak voltage, thickness of 
base metal, arc characteristic, spot welding time, downslope time, crater current, crater speed, crater 
voltage and post-flow time. 9 parameters of them, namely peak current, peak speed, peak voltage, 
thickness of base metal, arc characteristic, spot welding time, crater current, crater speed, crater 
voltage can be operated either through the control panel on the power supply part or through the control 
panel on the wire feeder part, and other parameters can be operated only through the control panel 
on the power supply part. Besides, Select the desired welding mode, base metal type, gas type, welding 
wire type and operation mode before any operation on parameters. 

 

 

 
 
 
 
 
 
 
 
 

For most of the parameters in pulsed MIG/MAG, see the contents of 6.3 section for reference. While 
a few of them are especially described as below. 

1)  Voltage type parameters 

Voltage type parameters include initial voltage, peak voltage and crater voltage, and they are used 
for adjusting the arc length. When voltage is high, arc length will be long, and when voltage is low, 
arc length will be short. 

2)  Arc characteristic 

It is located at “peak segment-current column-arc characteristic (-/+)”. Besides the function 
described in standard MIG/MAG welding, fine adjustment of arc length can be achieved through this 
parameter. 

Initial 

Current/Voltage 

Time 

Upslope 

Peak 

Downslope 

Crater 

Figure 6.3 Welding current and welding voltage in pulsed MIG/MAG

 

Summary of Contents for MIG 350P

Page 1: ...MODEL MIG 350P N316 MIG 400P N317 INVERTER WELDER OPERATOR S MANUAL L2040A SC A4 You Can buy this product at our E shop i prek galite sigyti m s el parduotuv je BUY NOW www e serpantinas com...

Page 2: ......

Page 3: ...pply monitoring panel 10 5 2 Details of the functional zones on the power supply monitoring panel 11 6 OPERATION OF CONTROL PANELS 15 6 1 General operation steps for the control panel on the power sup...

Page 4: ...chnologies of this product are patented Operate after reading this manual carefully 1 JASIC has the right to modify this manual at any time without prior notice 2 Though contents in this manual have b...

Page 5: ...orking position is safe Smoke gas may be harmful to health Keep your head away from smoke and gas to avoid inhalation of exhaust gas from welding Keep the working environment well ventilated with exha...

Page 6: ...bundant functions This product has many welding modes available such as MIG MAG pulse MIG MAG and double pulse MIG MAG etc At the same time there are many optional operation modes under each welding m...

Page 7: ...signing this product so as to meet the personalized requirements of users to the largest extent For example this product provides a variety of welding torch operating modes and user defined modes Besi...

Page 8: ...pe Maximum diameter of wire spool S200 S300 300mm S200 S300 300mm Wire diameter 0 8 1 6mm 0 8 1 6mm 3 3 Functional parameters MMA MIG350P N316 MIG400P N317 Welding current range 10 350A 10 400A Arc fo...

Page 9: ...MAG PULSE SERIES 7 3 4 External characteristic This machine is with constant voltage external characteristic in pulsed welding and MIG MAG welding while it is with constant current external character...

Page 10: ...onitoring panel 2 Front panel 3 Parameter adjustment knob 4 Power output terminal 5 Power output terminal 6 Interface for the control cable 7 Back panel 8 Air switch 9 Fuse 10 Socket for CO2 heater ap...

Page 11: ...Description Power source of the heater Input cable of the welding machine Breaker ON Breaker OFF Table 4 3 Symbols on the nameplate Symbol Description Symbol Description U0 Rated no load voltage Gas...

Page 12: ...Current column parameters selecting zone 3 Current column parameters display window 4 Abnormity indicator 5 Voltage column parameters display window 6 Voltage column parameters selecting zone 7 Weldi...

Page 13: ...e selecting key and the corresponding LED will be on when a certain kind of base metal is selected Note There is no such function in MMA Figure 5 4 Gas selecting zone It contains components such as ga...

Page 14: ...uch as time and pitch ratio peak parameters such as time current speed thickness arc characteristic voltage proportion and frequency base parameters such as current speed and voltage downslope paramet...

Page 15: ...The voltage column parameters include 4 parameters namely voltage V time s proportion and frequency Hz Voltage column parameters display meter can display system information actual welding voltage an...

Page 16: ...nnels are indicated with channel numbers Working channel means the channel being used currently 1 To access the channel management mode Press the channel key in standby mode the channel LED will be on...

Page 17: ...ing zone Figure 5 5 if necessary 5 Select the operation mode Select the desired operation mode by pressing the selecting key in the operation mode selecting zone Figure 5 9 if necessary 6 Select the p...

Page 18: ...TIG welding is a kind of DC TIG welding achieved by users in MMA welding through adding necessary gas path equipment connected to the welding machine and igniting arc by scraping the electrode Various...

Page 19: ...nitial voltage It is located at initial segment voltage column voltage V and it varies with the change of the initial current or initial speed Beside this parameter can be adjusted within a certain ra...

Page 20: ...lsed MIG MAG welding namely pre flow time initial current initial speed initial voltage upslope time peak current peak speed peak voltage thickness of base metal arc characteristic spot welding time d...

Page 21: ...he desired welding mode base metal type gas type welding wire type and operation mode before any operation on parameters For most of the parameters in double pulse MIG MAG see the contents of 6 3 sect...

Page 22: ...alue then gradually rises or drops to the preset value Release the torch trigger current drops gradually and arc stops 4T mode Push the torch trigger arc is ignited and current rises to the initial va...

Page 23: ...rrosive gas or materials in the ambient air should not exceed the standard content except for such materials produced in the process of welding 9 Never use this welding source for pipe thawing 10 Do n...

Page 24: ...ble connecting the workpiece the resistance would be greater and the welding current would be unstable Besides overheating would lead to fire hazard Therefore please connect the base metal reliably wi...

Page 25: ...istance between the power input and the enclosure and make sure such insulation resistance should be greater than 10 ohms 5 Put the machine into the original packing in dry location if it is not used...

Page 26: ...ilure problem The mains voltage is overly low Welding can be carried out after the mains voltage recovers There is no no load voltage output the protection LED is on and the meter displays Err 003 Air...

Page 27: ...roperly Table 8 3 Troubleshooting in MIG MAG Phenomena Cause Solution The wire feeder loses communication with the welding power supply The control cable is disconnected Connect the control cable The...

Page 28: ...egulator cannot be heated The plug of the heater is well connected Connect it well The heater wire is shorted Repair the heater wire The resettable fuse inside the machine functions Shut down the mach...

Page 29: ...OPERATOR S MANUAL MIG MAG PULSE SERIES 27 APPENDIX...

Page 30: ...OPERATOR S MANUAL MIG MAG PULSE SERIES 28...

Reviews: