OPERATOR’S MANUAL
·
MIG/MAG PULSE SERIES
- 13 -
Figure 5.7:
Current column parameters selecting
zone
9.Current; 10. Wire feed speed; 11. Base metal
thickness; 12. Arc characteristic
It contains components such as current column
parameters display meter, LEDs and selecting
key. The current column parameters include 4
parameters, namely current (A), wire feed speed
(m/min), thickness of base metal (mm) and arc
characteristic
(-/+).
Current
column
parameters display meter can display system
information, actual welding current and the
contents of the column parameters. Users can
select the desired parameters by pressing the
selecting key, and the corresponding LED will
be on when a certain parameter is selected.
Meanwhile, the contents of the selected
parameter will be displayed on the meter.
Note: The meter will display the actual current
when there is welding current output. To modify
a parameter, users should make corresponding
LED blink by pressing the selecting key.
Figure 5.8:
Voltage column parameters selecting
zone
13.Voltage; 14.Time; 15.Pulse duration ratio;
16. Frequency
It contains components such as voltage column
parameters display meter, LEDs and selecting
key. The voltage column parameters include 4
parameters, namely voltage (V), time (s),
proportion (%) and frequency (Hz). Voltage
column parameters display meter can display
system information, actual welding voltage and
the contents of the column parameters. Users can
select the desired parameters by pressing the
selecting key, and the corresponding LED will
be on when a certain parameter is selected.
Meanwhile, the contents of the selected
parameter will be displayed on the meter.
Note: The meter will display the actual voltage
when the main power circuit is connected. To
modify a parameter, users should make
corresponding LED blink by pressing the
selecting key.
Figure 5.9:
Operation mode selecting zone
It contains components such as operation mode
LEDs and selecting key.
There are 4 operation modes, namely spot
welding, 2T, 4T and programmed 4T . Users can
select the desired operation mode by pressing
the selecting key, and the corresponding LED
will be on when a certain operation mode is
selected.
Note: There is no such function in MMA.
Figure 5.10:
Parameter adjustment knob
It contains components such as parameter
control knob and adjustment indicator. All
welding parameters are set by adjusting this
knob. The adjustment indicator tells users that
the knob is effective only when the
corresponding parameter LED in the current
column or voltage column blinks.