For most of the parameters in double pulse MIG/MAG, see the contents of the MIG/MAG section for
reference. And the unique parameters in double pulse MIG/MAG are especially described as below
combined with Figure
1 LF peak current
It is located at
“
peak segment-current column-current (A)
”
, and it is the preset current for the LF peak
value running.
2 LF peak speed
It is located at
“
peak segment-current column-wire feed speed (m/min)
”
, and it is the preset wire feed
speed for the LF peak value running.
3 LF peak voltage
It is located at
“
peak segment-voltage column-voltage (V)
”
, and it is the preset voltage for the LF peak
value running.
4 LF pulse duration ratio
It is located at
“
peak segment-voltage column-proportion (%)
”
, and it is the percentage the LF peak
value time holding in the LF duration.
5 LF frequency
It is located at
“
peak segment-voltage column-frequency (Hz)
”
, and it is the reciprocal of the LF
duration (the sum of the LF peak value time and the LF base value time).
6 LF base current
It is located at
“
base segment-current column-current (A)
”
, and it is the preset current for the LF base
value running.
7 LF base speed
It is located at
“
base segment-current column-wire feed speed (m/min)
”
, and it is the preset wire feed
speed for the LF base value running.
8 LF base voltage
It is located at
“
base segment-voltage column-voltage (V)
”
, and it is the preset voltage for the LF base
value running.
Summary of Contents for MIG 350 Pulse Separate
Page 1: ...Operator Manual www jasic co uk MIG Series MIG 350 Pulse Separate JM 350P ...
Page 9: ...WWW JASIC CO UK 9 Controls Front Rear ...
Page 30: ...WWW JASIC CO UK 30 Electrical Schematic ...
Page 31: ...WWW JASIC CO UK 31 Parts list FRONT REAR ...
Page 32: ...WWW JASIC CO UK 32 LEFT SIDE RIGHT SIDE ...
Page 33: ...WWW JASIC CO UK 33 TOP ...