SPECIFICATIONS
Operating Pressure
150--175 psi 10--12 bar
Air Consumption (per cycle) 0.42 ft
3
10 L
Penetrating Shaft Diameter
0.63 in
16 mm
Control Handle
Pneumatic
Overall Dimensions (l x w x h)
16 x 9.5 x 16.5 in
406 x 241 x 419 mm
Weight
19.5 lbs
8.8 kg
INSTALLATION INSTRUCTIONS
IMPORTANT: ALWAYS DISCONNECT AIR HOSES IN
ACCORDANCE WITH OSHA’S LOCKOUT/TAGOUT
PROCEDURES
(29
CFR
1910.147)
BEFORE
PERFORMING ANY MAINTENANCE OR REPAIRS.
ALL WIRING MUST BE DONE IN ACCORDANCE WITH
NATIONAL, STATE AND LOCAL ELECTRICAL CODES.
Refer to Figure A on page 4 for numbered items.
1
I
nstall compressor:
1.1 Install compressor in a location that allows good
air circulation and easy access from stunning
box.
1.2 Install an air filter--regulator--lubricator at the op-
erator’s station.
Jarvis
part number 3022100 is
available.
1.3 Install hose assembly (item 48) to air filter--regu-
lator--lubricator.
Refer to Figure 1
.
2 Install balancer:
2.1 Install a balancer over the stunning box to sus-
pend AN--10K1.
Jarvis
part number 4042045 is
available.
3 Install AN--10K1 Pneumatic Stunner
:
3.1 Mount stunner (with balancer) hanging from a
rail that allows movement lengthways across the
stunning box.
Refer to Figure 2.
4 Fill the air filter--regulator--lubricator:
4.1 Use SAE 10 oil approved for USDA H1 service
to lubricate the air and to extend service life of
bumper (item 11).
Figure 1
Compressor
Air Pressure Line
Air--Filter--Regulator-- Lubricator
Hose Assy.
AN--10K1
Pneumatic
Stunner
Figure 2
Approx. 6.5 ft (2 m)
Rail
Hose Assy.
Balancer
Approx. 8 to 12 inches (200 to 300 mm)
Stunning Box
4.2
.
Adjust the lubricator to obtain approximately one
drop of oil for every three uses of the stunner.
5 Connect stunner to air pressure line:
Note: Make sure air supply valve is closed before con-
necting hose assembly to the air--filter--regulator--lubri-
cator; and that the system’s operating air pressure is a
minimum 150 psi (10.3 bar). If operating air pressure
falls below 150 psi, the release valve assembly (item 37)
will not close and air will escape.