Gland 25a (JIS F 8802)
(Dock supply)
NTE-182 AIS Transponder
Ground bolt
(Dock supply)
Ground sheet
(Attachment)
Fixing belts
(Attachment)
1500
mm or le
ss
Pole or Mast
(Dock supply)
RG-10UY
(Dock supply)
Example of reinforcement
(Dock supply)
*3
Protection sheet
(Attachment)
Rubbers (Attachment)
*4
Cautions
1.
*1: Seal this section with
self-bonding tape and then wrap with
vinyl tape.
2. *2: When the cable length is 500 mm
or longer, fix it with metal belts along
the pole.
Do not apply tension to the cable
during installation of the equipment.
3. *3: Seal this section with a sealing
material made from silicon before
fixing the transponder.
4.
The pole or mast must be
shock/vibration free.
5. The equipment must be installed
forward of the funnel to avoid smoke
and soot.
6. The equipment must be installed
where environmental temperature is
not higher than 55 deg. C.
7.
*
4: Seal the joint of N-type connector
with a sealing material made from
silicon in accordance with NTE-182
waterproofing procedures.
(If the joint ob N-type connector has
been sealed, it is not necessary to
seal.)
Installation Drawing of
NTE-182 AIS Transponder
2