10
Armor
clamp
Tightening
bracket
Washer Clamp
Ring
Center contact
Connector housing
Insulator
Gasket
(rubber)
Connection Procedure of Coaxial Connector
1. Parts (N-P-10U)
2. Procedure
Working
step
Shape Remarks
1
Cut the metal braid armor and insulation sheath
as shown left.
2
Ravel the braid conductor and cut the insulator as
shown left.
3
Gather up the metal braid armor and raveled braid
conductor, and insert the armor clamp, tightening
bracket, washer, gasket, and clamp, in order.
4
Fold the raveled braid as shown in the left figure, cut
them to the length of up to area A, and then stretch
them on the periphery of the clamp uniformly.
5
Dip-solder the conductor.
6
Pre-solder the inside of the center contact.
A