Ceiling
Height
Under Cabinet
Range hood
36”
Counter
Top
Max: 36”
24”
(610 mm) Min /
36”
(914 mm) Max
Min: 24”
Range
Hood
Height
Cabinet
Height
Countertop/Stove
This range hood has been designed to be installed under-cabinet, above a stove/hob. Before start-
ing the installation, consideration should be given as to how the installation will be carried out,
ensuring adequate space and clearances above the stove/hob.
When installed, the range hood must be positioned at least 24in (61cm) and at most 36in
(91.4cm) above the cooktop. NOTE: minimum of 30in (76cm) is required for gas stove top.
If the exhaust pipe is too long or there are too many bends, please select a suitable position to
install the range hood to ensure the appliance can suck-in smoke efficiently.
• This range hood must be ventilated to the outdoors.
• Do not ventilate the range hood into an attic or other enclosed areas.
• Use only metal/aluminum ductwork. Rigid metal/aluminum vent is recommended. Always keep
the duct clean to ensure proper airflow.
• Calculate the following figures before installation:
1. Distance from the floor to the ceiling.
2. Distance between the floor to the countertop/stove.
3. Distance between the cooking surface to the range
hood (recommend* 24” to 36”).
NOTE:
minimum of 30” is required for gas stove tops.
4. Height of hood and exhaust duct cover.
LOCATION REQUIREMENTS:
VENTILATION REQUIREMENTS:
Cabinet or
Single-piece
Chimney
(Optional)
Height & Clearance
5