35
MS5027PR
MECHANICAL ADJUSTMENT
REPLACEMENT AND ADJUSTMENT OF NEEDLE THREADER PLATE
* IF THE NEEDLE THREADER IS DAMAGED, REPLACE IT OR ADJUST AS FOLLOWS TO REPLACE
THE NEEDLE THREADER COVER:
1.
PULL OUT THE THREADER COVER (DRAWING. 1).
2.
TO ATTACH THE THREADER COVER, MATCH THE GROOVE TO THE PIN (B) AND INSERT THE
THREADER COVER (C).
ADJUSTMENT OF THREADER PLATE:
3.
IF THE HOOK (D) IS TOUCHING THE RIGHT OR LEFT SIDE OF NEEDLE EYE, LOOSEN
THE SETSCREW (E) AND SLIDE THE THREADER PLATE (H). (SEE DRAWING 2)
4.
IF THE HOOK (D) IS TOUCHING THE TOP OR BOTTOM SIDE OF NEEDLE EYE, REMOVE THE FACE
COVER AND LOOSEN THE SETSCREW (F) AND ADJUST THE THREADER POSITION SET PLATE (G).
HOOK (D)
THREADER KNOB
DRAWING 1
PIN (B)
THREADER POSITION SET PLATE (G)
SETSCREW
VIEW X
THREADER PLATE (H)
X
SETSCREW (E)
HOOK (D)
DRAWING 2