Setup
Desktop Robot JR3000
4. SENDING AND RECEIVING C&T DATA
The data sent and received between the robot and the PC is teaching data and customizing data, sent
as one unit (C&T data).
NOTE
To create backup data using a PC, refer to “2.6 Connecting to a PC (Ethernet)” in this manual, and
“2.2 Connecting to a PC (LAN Connection)” in
Maintenance
and make sure the robot and PC are
able to interface.
The robot has a data storage area and a work area. When you start the robot, the C&T data in the
storage area is copied to the work area. Data in the work area is used for teaching and running
programs. The data in the work area is deleted when the power to the robot is turned OFF.
When receiving data from the robot, the PC receives work area data. If sending data from the PC to
the robot, the sent data is automatically written to the storage area via the work area.
NOTE
If you are using JR C-Points II (optional), you can also perform the same operation by selecting
[Receive C&T Data] from the [Robot] pull-down menu in JR C-Points II.
Example: JR3203N-AC
Send/Receive
Data
PC
Backup Data
Storage Area
Work Area
35