![Janome AirThread 2000D Service Manual Download Page 9](http://html1.mh-extra.com/html/janome/airthread-2000d/airthread-2000d_service-manual_3479352009.webp)
7
Hook of looper cover position detecting arm
MODEL: AirThread 2000D
Replacing External Parts
Looper cover
Looper cover
To remove:
1. Remove the base plate.
2. Remove the setscrews (2 pcs.).
3. Release the hook of looper cover position detecting
arm from the looper cover shaft.
4. Remove the looper cover.
Setscrew
Hook of looper cover
position detecting arm
Looper
cover shaft
Setscrew
To attach:
1. Set the looper threader switch lever to the
"THREADING" (right side).
Make sure that the looper cover position detecting
arm comes in front of the looper. threader switch
lever connecting lever (shown as the looper cover
position detecting arm on top the looper threader
switch lever connecting lever in the figure).
2. Put the hook of looper cover position detecting arm on
the looper cover shaft.
3. Tighten the setscrews (2 pcs).
4. Attach the base plate.
Looper cover
position detecting arm
Looper cover shaft
Looper threader switch lever