19
TO ADJUST THE POSITION OF CHAINING FINGER
Correct Setting:
When set the needle plate setting knob to guide line S, chaining finger should be touch to side of needle
plate and tip of chaining finger should be same level to tip of needle on needle plate.
To adjust:
1. Remove the presser foot.
2. Set the needle plate setting knob to guide line S on needle plate.
3. Loosen two (2) setscrews A, and move chaining finger unit to correct position.
4. Tighten two (2) setscrews A.
5. Set the needle plate setting knob to guide line S and R on needle plate, and check the position of
chaining finger set plate unit.
6. Attach the presser foot.
Should be same level
Needle plate setting knob
Guide line S
Setscrew A
Guide line R
Chaining finger
set plate unite
To be touch