TO ADJUST THE CLEARANCE BETWEEN NEEDLES
AND FIXED NEEDLE GUARD
Correct Setting:
The clearance between needle and the fixed needle guard should be 0.1 to 0.4 mm.
To adjust:
1. Remove the foot and the needle plate and lower the needle to its lowest position.
2. Loose the setscrew A and adjust the position of the fixed needle guard.
3. Tighten the setscrew A.
4. Attach the needle plate and the foot.
Chaining finger
(Needle plate setting knob is to be “S”)
The clearance between the needle and
fixed needle guard
Chaining finger
Fixed needle guard
Tip of fixed needle guard
Needle plate setting knob
Fixed needle guard
0.1 ~ 0.4 mm
Needle
To be touch
Setscrew A