= Peak value
= Minimum value
= Supply
Technical data
Weight
:
250g
Calorific value
: 2,2MJ (610Wh)
Ambient conditions
Overvoltage class
: CATIII
Pollution degree
: 2
Ambient temperature
: -10°C .. +55°C
Storage temperature
: -20°C .. +70°C
Humidity
: 15% up to 95% without dew
Protection class
Front
: IP40 according to IEC529
Front with seal (option)
: IP42 according to IEC529
Back side
: IP20 according to IEC529
Protection class
: II = without protective wire
Installation place
: any
Height
: 0 .. 2000m over NN
Resistance against interf. (Industr. areas)
: EN50082-2:1995; IEC1000-4-,3, 10V/m
: IEC1000-4-4, 2kV; IEC1000-4-2, 8kV
Interference radiation (residential areas)
: EN55011 10.1997
Safety guidelines
: EN61010-1 03.1994 + A2 05.1996; IEC1010-1
Measurement
Measurement and supply voltage
: see type plate
Measuring inputs
Scanning frequency
:
1 Measurement/sec.
Rated pulse voltage
:
4kV
Signal frequency
: 45Hz .. 65Hz
Current measurement
: max. 300VAC against earth
Power consumption
: about 0,2 VA
Rated current at ../5A (../1A)
: 5A (1A)
Min. energying current
: 20mA
Current limit at ../1A
: 1,2A (sinus shape)
Current limit at ../5A
: 6A (sinus shape)
Overload
: 180A for 2 Sek.
Voltage measurement
: max. 300VAC against earth
Power consumption
196 .. 275V (see type plate)
: max. 13,4VA / Phase
98 .. 140V
(see type plate)
: max. 7,4VA / Phase
49 .. 76V
(see type plate)
: max. 2,6VA / Phase
Fuse
: 2A..6A (medium time-lag type)
Frequency of fundamental
: 45Hz .. 65Hz
Outputs
Type
: NPN-Transistor
Switching frequency
: max. 10Hz (50ms pulse width)
Operating current
: max. 50 mA (not short-circuit-proof)
Permissible rest current
: < 1mA
Operating voltage
: 5.. 24VDC, max. 30VDC
Connectable cables
One wire, multiple-wire, fine wire
: 0,08 - 2,5mm
2
Pin contacts
: 1,5mm
2