background image

www.janitza.de

17

Modules 800-CT8-A | 800-CON

3.10 Operating concept

Options to configure the basic device with current 
measuring module or to read measured values:

 ·Display and buttons on the basic device (user 

interface).

 ·GridVis

®

 network analysis software.

 ·RS-485 interface or Ethernet interface.

3.11 GridVis

®

 network analysis software

With the GridVis

®

 software, you have the perfect 

tool for programming, reading out and visualizing 
measurement data (download at www.janitza.de).

Performance characteristics of the GridVis

®

 

software

 ·Configuration of the device
 ·Graphic display of measured values
 ·Online help and tutorials

Connections to the PC (GridVis

®

 software)

Connections for communication between the PC 
and the basic device with modules can be found in 
chapter 6 on page 32.

INFORMATION

Please take note of the documentation of your 

basic device (without the module)! Basic or 

identical information and chapters, such as

 ·

Commissioning

 ·

Configuration

 ·

Technical data

 ·

Error messages

 ·

Procedure in the event of a malfunction, etc.

can be found in the usage information of your 

basic device.

A list of parameters and Modbus addresses with 

data on your basic device with module is available 

for you as a download at www.janitza.de.

INFORMATION

This user manual describes the modules and 

provides information on the operation of the 

modules via the basic device (UMG 801).

The GridVis

®

 software has an online help with 

tutorials.

Summary of Contents for 800-CT8-A

Page 1: ...transfer modules Extension modules for the UMG 801 User manual and technical data Janitza electronics GmbH Vor dem Polst ck 6 D 35633 Lahnau Support tel 49 6441 9642 22 Fax 49 6441 9642 30 Email info...

Page 2: ...8 A 800 CON www janitza de 2 Modules for UMG 801 Doc no 2 053 023 0a Date 11 2019 The German version is the original edition of the documentation 800 CT8 A current measuring module 800 CON transfer mo...

Page 3: ...t the current state of the information available to us Nonetheless we wish to point out that updates of this document are not always possible at the same time as technical refinements are implemented...

Page 4: ...nts and modules 11 2 5 Electrically qualified personnel 12 2 6 Warranty in the event of damage 12 2 7 Safety information for handling current transformers 12 3 Product description 14 3 1 800 CT8 A mod...

Page 5: ...ng the 800 CON transfer modules 31 6 PC connection 32 6 1 PC connection of the current measuring modules via the basic device UMG 801 32 6 2 PC connection of the basic device UMG 801 with current meas...

Page 6: ...800 CON transfer module 51 14 Dismounting 52 14 1 Dismounting the 800 CT8 A module 52 14 2 Exchanging an 800 CT8 A module 53 14 3 Dismounting the 800 CON module 54 15 Service and maintenance 56 15 1...

Page 7: ...www janitza de 7 Modules 800 CT8 A 800 CON...

Page 8: ...components matches the user manual This user manual applies to the modules for the UMG 801 Separate validities and distinctions are marked First make sure you have read and understood the usage inform...

Page 9: ...ad freight complete with accessories Observe special regulations for devices with built in batteries or rechargeable batteries Do not attempt to open or repair the device the module the component on y...

Page 10: ...on to a possible risk of injury Be certain to observe all of the information listed under this symbol in order to avoid possible injury or even death 2 2 Hazard levels Warning and safety information i...

Page 11: ...es 2 3 Product safety The devices components and modules reflect current engineering practice and accepted safety standards but hazards can arise nonetheless Observe the safety regulations and warning...

Page 12: ...tion for handling current transformers WARNING Risk of injury due to large currents and high electrical voltage on the current transformers Current transformers operated while open on the secondary si...

Page 13: ...www janitza de 13 Modules 800 CT8 A 800 CON...

Page 14: ...topologies e g UMG 801 with modules 800 CT8 A with flexible arrangement of your DIN rails for types see Technical Data in the switchboard cabinet or small distribution board Fig 800 CON module transfe...

Page 15: ...nnector Never touch or manipulate the contacts of the bus connector Never force the bus connector into the module Please refer to the chapter on this 4 Mounting on page 18 When handling transporting a...

Page 16: ...ork analysis software available at www janitza de you can configure your basic device with modules and read out data for analysis prerequisite PC connection with your basic device 3 8 Scope of deliver...

Page 17: ...tutorials Connections to the PC GridVis software Connections for communication between the PC and the basic device with modules can be found in chapter 6 on page 32 INFORMATION Please take note of th...

Page 18: ...road freight complete with accessories All usage information is also available as a download at www janitza de 4 1 Mounting the 800 CT8 A module Observe the mounting instructions for your basic device...

Page 19: ...ets of the basic device bus connector or into the sockets of the attached module so that the bus connectors devices are coupled Fig Side view UMG 801 and 800 CT8 A module Internal bus connector UMG 80...

Page 20: ...c device allows the mounting of up to 10 modules The maximum bus length of the JanBus is 100 m Always start and end your device and module series with end brackets cf Fig Example of a meter and module...

Page 21: ...ystems Cf chapter 5 3 Data transfer with 800 CON module on page 30 2 If this has not yet been done plug the bus connector JanBus interface included in delivery into the sockets on the rear of your mod...

Page 22: ...t protects the data cable from being torn out unintentionally Connect the transfer modules with the recommended data cables Please note the warnings and information below ATTENTION Improper handling m...

Page 23: ...connect your system from the power supply and check the condition of the bus connectors and the connections of your modules to the basic device JanBus interface If necessary push the contacts of the m...

Page 24: ...change pos 4 4 2 LEDs Blink orange during operation and indicate cyclic data exchange 5 4 current measurement inputs in the group terminals 1 2 3 4 5 6 7 8 Current measurements I1 I2 I3 I4 6 JanBus in...

Page 25: ...applied to the device and shown in the documentation in order to avoid possible injury or even death 3 Device type Device designation 4 DataMatrix code Coded manufacturer data 5 Manufacturer s logo L...

Page 26: ...module input bus connector Connector for insertion into the rear of the module 7 Transfer module input bus connector Sockets for module insertion 4 INFORMATION The transfer modules 800 CON of the set...

Page 27: ...Symbol for Danger sign General hazard symbol Be certain to observe the warning notices applied to the device and shown in the documentation in order to avoid possible injury or even death 3 Device typ...

Page 28: ...L3 L2 Consumer S1 S2 S1 S2 S1 S2 S1 S2 Consumer INFORMATION You can configure the current transformer ratios via the user interface of the basic device or conveniently using the Device configuration...

Page 29: ...for handling current transformers on page 12 Comply with the information and provisions in the usage information of your current transformers WARNING Risk of injury due to high currents and high elect...

Page 30: ...ta 800 CON transfer module on page 51 The recommended data cables can be found in chap 5 4 Data cable for connecting the 800 CON transfer modules on page 31 When setting up your meter and module topol...

Page 31: ...pprox 8 mm 0 31 in 1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 1 Twisted pair stranded hook up wire Lapp LiY 0 252 black blue Heat shrink tubing 8 7 6 5 4 3 2 1 225 mm 8 86 in Blue Black Blue Black Blue Black Blue...

Page 32: ...UMG 801 with current measuring module or your module series via the Ethernet interface Connection to a DHCP server and PC The DHCP server automatically assigns IP addresses to the basic device with mo...

Page 33: ...www janitza de 33 Modules 800 CT8 A 800 CON...

Page 34: ...asic device with modules and read out data for analysis prerequisite PC connection with your basic device 7 2 Module relevant menu items of the basic device with one module Home UMG 801 start screen 1...

Page 35: ...energy 1 4 Apparent energy 5 8 Apparent energy mod 1 1 4 Apparent energy mod 1 5 8 Multifunction channels Current measurement Temperature Configuration Ethernet TCP IP IP configuration IP address Netm...

Page 36: ...pears marked in blue Press button 3 Enter The item for the primary side of the current transformers I1 I4 blinks Use buttons 4 and 6 to change the position of the digit to be set and buttons 2 5 and 5...

Page 37: ...transformer Configuration in the GridVis software An assistant in the GridVis network visualization software helps with all module relevant settings Also note the usage information of the basic devic...

Page 38: ...227A 44 0 41 0 50 0 2 229A 2 229A 230 0V U1 U2 U3 I5 I6 I7 L6 L7 ESC Phasor diagram Mod 1 5 8 229 7V Menu phasor diagram Display Voltage L1 L2 L3 current L1 L2 L3 phase shift between voltage and curre...

Page 39: ...rent Mod 1 5 8 ESC Value Max Avg THD I 1 4 THD I 5 8 THD I ESC THD I Mod 1 1 4 THD I Mod 1 5 8 L1 L2 L3 L4 201 1 166 4 166 4 166 3 207 0 166 4 166 4 166 3 222 2 166 4 166 4 166 3 THD I Mod 1 1 4 ESC V...

Page 40: ...r 0 00kvar 0 00kvar 0 00kvar 0 61kVA 0 20kVA 0 20kVA 0 20kVA Power summary Mod 1 5 8 P S Q ESC Active power 1 4 Active power 5 8 Active power ESC Active power Mod 1 1 4 Active power Mod 1 5 8 L1 L2 L3...

Page 41: ...0 03kvar 0 01kvar 0 01kvar 0 01kvar Value Avg Apparent power 1 4 Apparent power 5 8 Apparent power Mod 1 1 4 Apparent power Mod 1 5 8 Apparent power ESC L1 L2 L3 0 58kVA 0 19kVA 0 19kVA 0 19kVA 0 48k...

Page 42: ...1 4 for L1 L2 L3 with cos phi and sums Display Power factor 5 8 for L5 L6 L7 with cos phi and sums Submenu Power factor Power Energy Multifunctional channels Configuration System information Menu Rea...

Page 43: ...Apparent energy Mod 1 1 4 Apparent energy Mod 1 5 8 Apparent energy ESC Total 2 7kVAh Apparent energy Mod 1 1 4 Sum L1 L3 ESC ESC Apparent energy 1 4 Apparent energy 5 8 Apparent energy Apparent ener...

Page 44: ...stem informationen Menu Main device Module 1 System information ESC Menu System information Display System information 2 2 Display System information 1 2 Type Serial no Position 800 CT8 A 48000111 1 M...

Page 45: ...www janitza de 45 Modules 800 CT8 A 800 CON...

Page 46: ...ale Dimensions in mm Front view Bottom view Rear view Top view View from left Plug for module insertion Bus connector for transfer module Output Connector for insertion into the socket for the bus con...

Page 47: ...ss II according to IEC 60536 VDE 0106 part 1 a ground wire connection is not required Rated temperature range 10 C 14 F to 55 C 131 F Relative humidity 5 to 95 at 25 C 77 F no condensation Pollution d...

Page 48: ...I Rated surge voltage 2 5 kV Power consumption Approx 0 2 VA Ri 5 m Sampling frequency 8 3 kHz Frequency of the fundamental oscillation 40 Hz 70 Hz Harmonics 1 9 odd only Connecting capacity of the te...

Page 49: ...0 12 6 kW 0 999 GW Total reactive power QA Qv 1 IEC61557 12 0 16 6 kvar 0 999 Gvar Total apparent power SA Sv 0 5 IEC61557 12 0 12 6kVA 0 999 GVA Total active energy Ea 0 5 IEC61557 12 0 5S IEC62053...

Page 50: ...ew View from left Plug for insertion into the basic device or an attached module Bus connector for the output transfer module Sockets for module insertion Bus connector for the input transfer module C...

Page 51: ...24 16 Wire ferrules non insulated 0 2 1 5 mm2 AWG 26 16 Wire ferrules insulated 0 2 1 mm2 AWG 26 18 Tightening torque 0 2 0 25 Nm 1 77 2 21 lbf in Strip length 7 mm 0 2756 in General Net weight with...

Page 52: ...anBus interface and carefully unlock the bottom bolts of the module with a screwdriver Fig Dismounting the 800 CT8 A module Bottom bolt JanBus interface for further modules JanBus interface Bus connec...

Page 53: ...n chapter 14 Dismounting on page 52 2 Replace a defective module with an intact one for example see chapter 4 Mounting on page 18 3 Supply your meter and module topology your system with voltage 4 Use...

Page 54: ...nBus interface of the transfer module from the basic device and or the connected module by pulling them out 5 Unlock the bottom bolts of the transfer module Recommendation Use a screwdriver be careful...

Page 55: ...www janitza de 55 Modules 800 CT8 A 800 CON...

Page 56: ...elect a corresponding update file and carry out the update INFORMATION This user manual describes the modules and provides information on the operation of the modules via the basic device In addition...

Page 57: ...saving measured values and configuration data INFORMATION The basic device stores the following measured values every 5 minutes at the latest S0 meter readings Min max average values Energy values wo...

Page 58: ...Janitza electronics GmbH Vor dem Polst ck 6 D 35633 Lahnau Support tel 49 6441 9642 22 Email info janitza de www janitza de...

Reviews: