Page 15
ENGLISH
Jandy
®
JRT Series Heat Pumps
|
Installation and Operation Manual
5. Restore power to the heat pump and the pool/spa
control system.
Confi gure the Control Panel
1. Make sure the control is in the
OFF
mode.
2. To enter the Service Setup mode, press and hold
the
MENU
,
POOL
, and
SPA
buttons for 5
seconds.
NOTE
The display will revert back to
OFF
after one
minute since the last key press.
3. Press the
Up
or
Down
button to display
REMOTE
. Press the
MENU
button. The
SELECT REMOTE OFF
(default remote)
appears, use the
Up
or
Down
button to scroll
through the Remote options. When you reach
HI-
LO-COM
, press the
MENU
button to select the
remote. Press
POOL
or
SPA
to exit the Service
Setup mode.
Two-Wire Connection to an AquaLink
®
RS or
TSTAT
A 2-wire remote will only control one function; heating
or cooling. It cannot control both functions with the
remote control.
Confi gure the AquaLink RS Control
System
1. Turn off the power to both the pool/spa control
system and the heat pump unit.
2. Connect two (2) wires to the AquaLink RS green
10-pin terminals 1 and 2.
3. Put DIP S2-1 (pin #1 of the 4 position DIP switch)
into the ON position (see Figure 11).
Install the Remote TSTAT
1. Turn off the power to both the pool/spa control
system and the heat pump unit.
2. Remove the screws that attach the service/access
panel to the heat pump unit and the cover to the
junction box (See Figure 9).
3. Run the wires from the pool/spa control system
into the conduit connection labeled “low voltage
connection”, located on the lower right hand side
of the heat pump (See Figure 9).
4. Connect the wiring from the pool/spa control
system to the heat pump remote control terminal
(See Figure 10b).
5.
Restore power to the heat pump and the pool/spa
control system.
Confi gure the Control Panel
1. Make sure the control is in the
OFF
mode.
2. To enter the Service Setup mode, press and hold
the
MENU
,
POOL
, and
SPA
buttons for 5
seconds.
NOTE
The display will revert back to
OFF
after one
minute since the last key press.
3. Press the
Up
or
Down
button to display
REMOTE
. The
SELECT REMOTE OFF
(default remote) appears, use the
Up
or
Down
button to scroll through the Remote options. When
you reach
REMOTE TSTAT
, press the
MENU
button to select the remote. Press
POOL
or
SPA
to exit the Service Setup mode.
4. Press
SPA
. For heating, adjust the setpoint to the
maximum setting. For chilling, adjust the setpoint
to the minimum setting.
Figure 10a.
Remote Pool-Off-Spa Connection
(3-Wire Connection)
Figure 10b.
AquaLink RS or Remote TSTAT
Connection (2-Wire Connection)