Page 9

Cartridge Filters - CJ Series Filter

Section 5. Filter Disassembly and 

Assembly

WARNING

NEVER 

attempt to assemble, dis as sem ble or adjust 

the filter when there is pressurized air in the system. 
Starting the pump while there is any pressurized air 
in the system can cause the filter lid to be blown off, 
which can cause death, serious personal injury or 
property dam age.

5.1  Filter Element Removal

1.      Turn 

off

 the filter pump and turn breaker off.

2.      Open air release valve on top of the filter tank 

to release all pressure from inside the tank and 
system (see Fig. 6). Close any filter isolation 
valves on the system to prevent flooding.

3.      Open the filter tank drain. When the filter tank has 

drained, close the drain.

4.      Remove the locking ring by squeezing up on the 

handles and turning it counterclockwise.

5.      Remove the top of the filter. Inspect the tank 

o-ring for damage. Clean or replace the o-ring as 
necessary.

6.      Remove the Upper Bearing Assembly from the top 

of the filter. Remove the filter element from the 
tank bottom and clean or replace as necessary.

7.      Place the new or cleaned filter element into the 

tank bottom. Place the Upper Bearing Assembly 
on top of the filter.

8.      Use a Silicone based lubricant on the new or 

cleaned o-ring and place the o-ring onto the tank 
bottom.

9.      Place the tank top onto the tank bottom. Be sure 

the tank halves are seated properly.

10.    Install the locking ring (see Section 3.4, "Locking 

Ring Installation").

11.    Follow steps 5 thru 8 under Section 4.1, "New 

Pool and Seasonal Start-Up".

Figure 6.  Filter Element Removal

Locking 
Ring

Tank Top

Upper Bearing 
Assembly

Filter Element

Tank Bottom

Air 
Release 
Valve

Tank Retaining 
Ring

Summary of Contents for CJ200

Page 1: ...installation and or operation can create dangerous high pressure which can cause the filter lid to be blown off possibly causing death serious injury or property damage Improper installation and or op...

Page 2: ......

Page 3: ...1 Filter Location 6 3 2 Filter Preparation 6 3 3 Filter Installation 7 3 4 Locking Ring Installation 8 Section 4 Start Up and Operation 8 4 1 New Pool and Seasonal Start up 8 Section 5 Filter Disassem...

Page 4: ...mediately 5 Be sure that the filter is properly mounted and positioned according to these installation instructions 6 Do not pressure test above 50 PSI Pressure testing must be done by a trained pool...

Page 5: ...the total volume of water in your pool two to four times in a 24 hour period 2 3 General Requirements 1 For best overall performance place the system as close to the pool as possible 2 The filter sho...

Page 6: ...d servicing 6 Position the filter to safely direct water drainage Align the air release valve to safely direct purged air or water 7 If the filter is to be installed below the water level of the pool...

Page 7: ...0359100 Anchor Brackets 3 3 Filter Installation 1 This filter operates under pressure When the locking ring is properly seated and the filter is operated without air in the water system this filter wi...

Page 8: ...it onto the filter Turn the locking ring clockwise until you hear it snap over the tabs on the lower half of the tank Section 4 Start Up and Operation 4 1 New Pool and Seasonal Start up 1 Turn off the...

Page 9: ...locking ring by squeezing up on the handles and turning it counterclockwise 5 Remove the top of the filter Inspect the tank o ring for damage Clean or replace the o ring as necessary 6 Remove the Uppe...

Page 10: ...3 screws into the support and hand tighten the screws Do not use a wrench 7 Follow steps 7 thru 10 under Section 5 1 Filter Element Removal 8 Follow the steps in Section 4 1 New Pool and Seasonal Sta...

Page 11: ...aks at least once a week 2 Keep the pressure gauge in good working order If you suspect a problem with the gauge Jandy recommends you call a qualified service technician to do any work on the filter p...

Page 12: ...age Check and clean strainer baskets Check all connections between pool intake and pump Check all lines for debris or partially closed valves Clean or replace filter cartridge per instructions Fill po...

Page 13: ...ather Tube Support w Screws CJ200 set of 3 screws R0557802 12 Tank O ring R0557900 13 Cartridge to Plenum Adapter w Screws R0558000 14 Plenum w Gasket R0558100 15 Half Unions w O rings set of 3 and Dr...

Page 14: ...Page 14 Section 10 Head Loss Curves 10 1 Jandy Cartridge Filter CJ Series...

Page 15: ...Page 15 Cartridge Filters CJ Series Filter NOTES...

Page 16: ...w rates outside the published minimum and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or im...

Reviews: