Cartridge Filters - CJ Series Filter

Section 6. Maintenance

6.1 General 

Maintenance

1.      Wash outside of filter with a mild detergent or TSP 

(tri-sodium phosphate) and water. Rinse off with 
a hose. 

Do not use solvents to clean the fi lter, 

solvents will damage the plastic components of  
the fi lter. 

2.      Check pressure during operation at least once a 

week.

3.      Remove any debris from the skimmer basket and 

hair/lint pot on pump.

4.      Check pump and filter for any leaks. If any leaks 

develop, turn off the pump and call a qualified 
pool service technician.

5.      Product safety signs or labels should be 

periodically inspected and cleaned by the product 
user as necessary to maintain good legibility for 
safe viewing.

6.      Product safety signs or labels should be replaced 

by the product user when a person with normal 
vision, including corrected vision, is no longer 
able to read the safety signs or label message panel 
text at a safe viewing distance from the hazard. 
In cases where the product has an extensive 
expected life or is exposed to extreme conditions, 
the product user should contact either the product 
manufacturer or some other source to determine 
means for obtaining replacement signs or labels.

7.      Installation of new replacement safety signs or 

labels should be in accordance with the sign or 
label manufacturer's recommended procedure.

6.2 Pressure 

Gauge

Caution

Maintain your pressure gauge in good working order. 
The pressure gauge is the primary indicator of how 
the filter is operating. 

1.      During operation of the filtration system, check 

the pressure gauge/air release assembly for air or 
water leaks at least once a week.

2.      Keep the pressure gauge in good working order. 

If you suspect a problem with the gauge, Jandy 
recommends you call a qualified service technician 
to do any work on the filter/pump system.

6.3  Cleaning the Filter Cartridge

1.      Turn 

off

 the filter pump and turn breaker off.

2.      If the filter is installed below pool level, close any 

filter isolation valves to prevent flooding.

3.      Open the air release valve on top of the filter and 

wait for all air pressure to be released.

4.      Open filter tank and remove cartridge element (see 

Section 5.1 "Filter Element Removal". Place it 
upright in an area suitable for washing.

5.      Use a garden hose and nozzle to wash each pleat 

of the element.

NOTE

  Algae, suntan oil, calcium and body oils can form 

coatings on filter element which may not be removed 
by normal hosing. To remove such materials, soak 
the element in de-greaser and then a de-scaler. Your 
local pool shop will be able to recommend suitable 
products.

6.      Replace the cartridge back into the filter tank. 

Inspect the o-ring for cracks or wear marks. 
Place the o-ring back onto the filter tank bottom. 
Replace the top of the tank. Place the filter locking 
ring on the filter and tighten (see Section 3.4 
"Locking Ring Installation"). 

7.      Reopen the isolation valves if they were closed.

8.      Stand clear of the filter, start the pump and 

circulate the water until water sprays out of the air 
release valve. Close the air release valve. The filter 
is now back in operating mode

Section 7. Winterizing

1.      Turn 

off 

the pump and circuit breakers.

2.      Open air release valve on top of the filter. 

Do not 

remove.

3.      Loosen the drain plug at the base of the filter to 

ensure that the tank is empty. 

4.      Drain circulation system of all water.

5.      Cover the system with a tarpaulin or plastic sheet 

to protect it from the weather.

Summary of Contents for CJ200

Page 1: ...installation and or operation can create dangerous high pressure which can cause the filter lid to be blown off possibly causing death serious injury or property damage Improper installation and or op...

Page 2: ......

Page 3: ...1 Filter Location 6 3 2 Filter Preparation 6 3 3 Filter Installation 7 3 4 Locking Ring Installation 8 Section 4 Start Up and Operation 8 4 1 New Pool and Seasonal Start up 8 Section 5 Filter Disassem...

Page 4: ...mediately 5 Be sure that the filter is properly mounted and positioned according to these installation instructions 6 Do not pressure test above 50 PSI Pressure testing must be done by a trained pool...

Page 5: ...the total volume of water in your pool two to four times in a 24 hour period 2 3 General Requirements 1 For best overall performance place the system as close to the pool as possible 2 The filter sho...

Page 6: ...d servicing 6 Position the filter to safely direct water drainage Align the air release valve to safely direct purged air or water 7 If the filter is to be installed below the water level of the pool...

Page 7: ...0359100 Anchor Brackets 3 3 Filter Installation 1 This filter operates under pressure When the locking ring is properly seated and the filter is operated without air in the water system this filter wi...

Page 8: ...it onto the filter Turn the locking ring clockwise until you hear it snap over the tabs on the lower half of the tank Section 4 Start Up and Operation 4 1 New Pool and Seasonal Start up 1 Turn off the...

Page 9: ...locking ring by squeezing up on the handles and turning it counterclockwise 5 Remove the top of the filter Inspect the tank o ring for damage Clean or replace the o ring as necessary 6 Remove the Uppe...

Page 10: ...3 screws into the support and hand tighten the screws Do not use a wrench 7 Follow steps 7 thru 10 under Section 5 1 Filter Element Removal 8 Follow the steps in Section 4 1 New Pool and Seasonal Sta...

Page 11: ...aks at least once a week 2 Keep the pressure gauge in good working order If you suspect a problem with the gauge Jandy recommends you call a qualified service technician to do any work on the filter p...

Page 12: ...age Check and clean strainer baskets Check all connections between pool intake and pump Check all lines for debris or partially closed valves Clean or replace filter cartridge per instructions Fill po...

Page 13: ...ather Tube Support w Screws CJ200 set of 3 screws R0557802 12 Tank O ring R0557900 13 Cartridge to Plenum Adapter w Screws R0558000 14 Plenum w Gasket R0558100 15 Half Unions w O rings set of 3 and Dr...

Page 14: ...Page 14 Section 10 Head Loss Curves 10 1 Jandy Cartridge Filter CJ Series...

Page 15: ...Page 15 Cartridge Filters CJ Series Filter NOTES...

Page 16: ...w rates outside the published minimum and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or im...

Reviews: