ORIGINAL AQUAPURE, PURELINK, & CM3 TESTS
AquaPure Sensor Readings Test - Front
Board
Flow Sensor
R-Temp H-Temp Salinity
Disconnect Flow Sensor Before
Using Test Switches
Salinity – 2.8 GPL
R-Temp – 75 F
H- Temp 91 F
RED BLK YEL GRN
1 2 3 4
To help determine if a fault is with the front board or the sensor, there are self diagnostic tests put on the
front board. To use these, you will need access to the front board display side and the corner of the front
board next to the red four pin connector.
-On an AquaPure, you will need to remove the front cover and use both sides of the cover.
-On a PureLink, drop the power center down and you will be able to access both sets of buttons at the
same time.
1-8 75 VAC
2-7 65 VAC
3-6 21 VAC
4-5 120 mVAC
(with Cell On)
T
rans
fo
rm
er
CELL ON
CELL RESTING
FLOW
CELL REVERSING
ADD SALT
SERVICE
CHLORINE
PRODUCTION RATE
A
B
C
?
Salinity
D
?
Pool
Temperature
-Boost-
Power On
1. Set Unit to “00” % for 24 Hours. Broadcast or Spread Salt into Shallow End of Pool.
2. Do not Add Salt through Skimmer, Main Drain or Surge Tank.
Directions for Adding Salt:
Boost – 24 Hour 100% Chlorine Production Cycle – Refer to Manual –
---- To Enter Boost Mode Press and Hold “Temperature” Button 10 Seconds
Pool Temperature – Temperature of Water at Flow Sensor
Cell On – Making Chlorine
Cell Resting – Off Portion of Chlorine Production Cycle
Flow – Water Flow Present
Cell Reversing – Automatic Cleaning Cycle in Progress
Add Salt – Salinity Should be 3.0 – 3.5 Grams / Liter
Service – Refer to Manual –
---- To Silence Audible Service Alarm Press and Hold “Salinity” Button 5 Seconds
Display side of AquaPure
Upper right side of front board on an AquaPure
31
3) Press and hold the test button marked H-Temp. While still pressing the test button, press the
‘Salinity’ key (‘C’) together with the ‘Chlorine Production Rate’ arrow down key (‘A’) on the front
cover of the unit. The LCD should read 91
°
F or 33
°
C.
(
±
1
°
)
If the readings are correct then the front board is O.K. and the problem is with the sensor.
If the readings are different then it indicates that there is a problem with the front board.
Turn off power and replace the failed component. Restart the unit and wait for system diagnostics.
(Approximately 5 minutes).
PureLink Sensor Readings
Test- Front Board
Disconnect the sensor from the front board for the
following tests.
1) Press and hold the test buttons marked Salinity
and R-Temp. While still pressing these test
buttons, press the ‘Salinity’ key (‘C’) on the front
cover of the unit. The LCD should read 2.8gpl.
(
±
.1)
*
2) Press and hold the test buttons marked Salinity
and R-Temp. While still pressing these test
buttons, press the ‘Pool Temperature’ key (‘D’). It
should read 75
°
F or 24
°
C.
(
±
1
°
)
*Note: In some cases the front board may have been recalibrated. This will show a different
gpl then what is listed. If the front board or housing has any markings that indicate it has been
recalibrated, contact Zodiac technical support at 800-822-7933. Otherwise replace the front
board.
PureLink front board access
R-Temp
H-Temp
Salinity