![Jandy AquaPure Workbook Download Page 18](http://html2.mh-extra.com/html/jandy/aquapure/aquapure_workbook_3324451018.webp)
TROUBLESHOOTING - TRANSFORMER VOLTAGE
1 Amp FUSE
19 VAC
VAC 1
VAC 2
65 VAC
75 VAC
+24 VDC
+5 VDC
COMMON
+12 VDC
DCV
W
2000K
200K
20K
2K
h
FE
2
20
200
1000
200
750
PNP
NPN
OFF
200m
DCA
20m
200m
10A
200
ACV
200
µ
2000
µ
19
Third Test:
Set the meter to 200 ACV or higher. Put the leads on VAC 1 & VAC 2 of the 19 VAC
test points. The voltage should be between 17 to 24.
If no voltage is present, check 1 Amp Fuse on PIB.
If the voltage is outside the above range, replace the Transformer.
18