ORIGINAL AQUAPURE, PURELINK, & CM3 TESTS
Flow Sensor
R-Temp H-Temp Salinity
Disconnect Flow Sensor Before
Using Test Switches
Salinity – 2.8 GPL
R-Temp – 75 F
H- Temp 91 F
Test Point
Common
A to C -- 21 VAC
K to H -- 120 mVDC
A B C D E F G H J K
Test
Points
RED BLK YEL GRN
1 2 3 4
Voltage on Front Board
(All test point voltages are marked on the board)
Test the voltage from the
back board at test points
A & C.
-If the voltage is not
21
VAC
(
±
10%)
confirm that the
ribbon cable that
connects the back board
to the front board is not
damaged and that it is
seated correctly and
retest. If the retest
remains outside the
required voltage, perform
a back board test.
DCV
W
2000K
200K
20K
2K
200
µ
h
FE
2000
µ
2
20
200
1000
200
750
PNP
NPN
OFF
200m
DCA
20m
200m
10A
200
ACV
21
30
Flow Sensor
R-Temp H-Temp Salinity
Disconnect Flow Sensor Before
Using Test Switches
Salinity – 2.8 GPL
R-Temp – 75 F
H- Temp 91 F
Test Point
Common
A to C -- 21 VAC
K to H -- 120 mVDC
A B C D E F G H J K
Test
Points
RED BLK YEL GRN
1 2 3 4
Cell Current on Front Board
(All test point voltages are marked on the board)
Cell Current is tested
through DC Millivolts.
Test the current from the
cell at test points H & K.
-If the voltage is higher
than 160 mVDC or less
than 120 mVDC, confirm
that the ribbon cable that
connects the back board
to the front board is not
damaged and that it is
seated correctly and
retest. If the retest
remains outside the
required voltage, perform
a back board test.
Informational Note:
20 millivolts =
1 ampere on a 1400 unit
40 millivolts =
1 ampere on a 700 unit